Safety switching, expansion unit and time delay module<br />

The safety switching unit, its corresponding expansion unit and<br />

the time delay modules are main elements of a safety switching<br />

system in the switching cabinet; they bear the VGB test mark.<br />

They serve to implement, for example, functions such as<br />

• Emergency Off,<br />

• Drive enable,<br />

• Guard interlock,<br />

to prevent hazards for personnel and machines.<br />

The safety switching unit is self-monitoring and ensures that<br />

machinery can only start if there are no faults, or it shuts down<br />

in the event of a fault.<br />

In conjunction with the safety switching unit, the time-delay modules<br />

allow a defined Off-delay which is preset and individually<br />

adjustable.<br />

The safety switching units can be used for all equipment<br />

covered by the regulations of DIN EN 60 204 Part 1.<br />

The modules are easily fitted by snap-mounting on a<br />

35 x 15 mm DIN rail to DIN EN 50 022.<br />

Ordering data Order No.<br />

Safety switching unit H100 6FM8 090 - 0AS01<br />

1 channel/3 release circuits<br />

Safety switching unit H110 6FM8 090 - 0AS02<br />

Extension for 2 × 4 release circuits<br />

Time-delay module H120<br />

6FM8 090 - 0AS03<br />

0.2 to 22.5 s<br />

Time-delay module H121<br />

6FM8 090 - 0AS04<br />

0.1 to 6.1 s<br />

Safety switching unit H100-2K-Z 6FX2 006 - 2AC01<br />

dual-channel redundant with earth<br />

and cross-circuit recognition,<br />

RC-delayed relay K1<br />

Reference manual 6FM8 090 - 0AS00<br />

in German<br />

Technical specifications<br />

System Components<br />

Safety switching unit<br />

Unit type H100 H110 H120 H121 H100-2K-<br />

Z<br />

Cable connection via plug-in 2×5 2×16 2×10 2×10 2×16<br />

terminal strip 2×14 2×16<br />

Conductor cross-section up to 2.5 mm 2 (AWG 12)<br />

up to 1.5 mm 2 (AWG 14)<br />

PE-terminal tap-connector 4.8 mm or<br />

cable lug<br />

Supply voltage<br />

Operating voltage Ue Permissive range<br />

24 V DC<br />

20.4 to 28.8 V DC<br />

Power consumption [VA] 1.5 2 0.5 0.5 1.5<br />

Switching voltage AC/DC 230/24 – – 230/24<br />

Switching current<br />

Utilizing categories<br />

(DIN VDE 0660, part 200)<br />

6/6 – – 6/6<br />

AC-12 230 V, 6A – – 230 V, 6A<br />

AC-15 230 V, 2A – – 230 V, 2A<br />

AC-13 24 V, 6A – – 24 V, 6A<br />

Permissive ambient temp.<br />

• in storage and transportation –25 °C to +70 °C<br />

• in operation 0 °C to +55 °C<br />

Mech. ambient condition Class 3 M3<br />

(DIN EN 60 721-3-3)<br />

Degree of protection<br />

(DIN VDE 0470 Part 1)<br />

IP 20<br />

Degree of protection<br />

(DIN VDE 0106 Part 100)<br />

I<br />

Weight approx. [g] 450 650 450<br />

Dimension (H × D) 110 mm × 210 mm<br />

Width [mm] 44 44 44 44<br />

Siemens NC Z · 2002/2003<br />