23.12.2012 Views

Pre-assembled Cables - Setams SA

Pre-assembled Cables - Setams SA

Pre-assembled Cables - Setams SA

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />

With connector box<br />

SIMODRIVE<br />

611 digital<br />

Drive module<br />

with digital<br />

setproint<br />

interface<br />

X411<br />

FDD and MSD<br />

performance<br />

control<br />

for 1FN<br />

motors<br />

U2, V2, W2<br />

2)<br />

6FX@ 002 - 2CA31 - 1@@0 £ 50 m<br />

6FX7 002 - @@@@ - 1@@0<br />

£ 50 m<br />

or<br />

Connection of the temperature sensor 3)<br />

have to be made by the customer<br />

6FX8 008 - 1BD71 - 1@@0<br />

(supplied by meter)<br />

6FX7 008 - @@@@@ - 1@@0<br />

£ 50 m<br />

Tripping device<br />

3RN1<br />

(supplied by meter)<br />

Connector-Box<br />

1FN1 910 -<br />

0AA20 - 0AA0<br />

<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />

Overview of Connection Diagrams<br />

SIMODRIVE 611 digital, for 1FN motors<br />

Adapter cable<br />

310 128...<br />

310 123...<br />

1FN1 Linear motor<br />

with temperature<br />

3)<br />

sensor<br />

1) Cable can be obtained from the manufacturer of the linear scale. 3)<br />

G_NC02_en_00052<br />

The cables for the temperature sensor are run in the power<br />

2) For 6FX8 ... £ 25 m<br />

cable 6FX700.-... and must be coupled out before the<br />

converter.<br />

Alternative connection without connector box<br />

SIMODRIVE<br />

611 digital<br />

Drive module<br />

with digital<br />

setpoint<br />

interface<br />

X411<br />

FDD and MSD<br />

performance<br />

control<br />

for 1FN<br />

motors<br />

U2, V2, W2<br />

6FX@ 002 - 2CH00 - 1@@0 2)<br />

£ 50 m<br />

or<br />

313 791...<br />

Adapter cable 1)<br />

6FX@ 002 - 2CG00 - 1@@0 310 128...<br />

£ 50 m<br />

310 123...<br />

6FX7 002 - @@@@ - 1@@0<br />

£ 50 m<br />

or<br />

Connection to the temperature sensor<br />

have to be made by the customer<br />

6FX8 008 - 1BD71 - 1@@0<br />

(supplied by meter)<br />

6FX7 008 - @@@@@ - 1@@0<br />

£ 50 m<br />

3)<br />

Tripping device<br />

3RN1<br />

(supplied by meter)<br />

Adapter cable 1)<br />

Please observe maximum permissible cable lengths (e.g. ≤ 50 m). If greater cable lengths are used, system malfunctions may occur.<br />

The order number code for cable variant 6FX@ ..., the general length key (-1@@@), and recommended lengths can be found on the<br />

foldout pages.<br />

1)<br />

Cable included<br />

in Hall-effect<br />

sensor box<br />

package content<br />

Evaluation via the<br />

PLC or at the<br />

UE/R terminal<br />

X121-64<br />

2-core<br />

Evaluation via the<br />

PLC or at the<br />

UE/R terminal<br />

X121-64<br />

2-core<br />

Direct linear<br />

incremental encoder<br />

sin/cos 1 Vpp<br />

LS 186(C)<br />

LS 486(C)/LF 481(C)<br />

Hall-effect sensor box<br />

(optional)<br />

1FN3 Linear motor<br />

with<br />

3)<br />

temperature sensor<br />

Direct linear absolute<br />

value encoder<br />

(EnDat)<br />

LC 181/LC 481<br />

Direct linear incremental<br />

encoder sin/cos 1Vpp LS 186 (C)<br />

LS 486 (C)<br />

1FN1 Linear motor<br />

with<br />

3)<br />

temperature sensor 3) 3)<br />

1FN3 Linear<br />

motor with temperature<br />

sensor 3)<br />

3)<br />

1) Cable can be obtained from the manufacturer of the linear scale. 3)<br />

G_NC02_en_00053<br />

The cables for the temperature sensor are run in the power<br />

2) For 6FX8 ... £ 25 m.<br />

cable 6FX700.-... and must be coupled out before the<br />

converter.<br />

Siemens NC Z · 2002/2003<br />

2/35<br />