Pre-assembled Cables - Setams SA

Pre-assembled Cables - Setams SA Pre-assembled Cables - Setams SA

setams.sa.com.ar
from setams.sa.com.ar More from this publisher
23.12.2012 Views

2 Pre-assembled Cables Overview of Connection Diagrams SINUMERIK 840Di SINUMERIK 840Di PCU 50/PCU 70 5) 2/24 MCI board extension (optional) Contained in the MCI Board Extension scope of supply X2 X2 MCI board X121 X111 MPI X101 PROFIBUS-DP Standard PC interfaces 1) Cable distributor 6FX2 006-1BA02 MPI cable see page A/2 £ 25 m 6) £100 m 12 Mbit/s SIMATIC DP ET 200 e.g. ET 200M Siemens NC Z · 2002/2003 6FX8 002-4AA41-1@@0 4) £ 25 m 6FX8 002-4AA21-1@@0 4) £ 25 25 m (82 ft) 6FX8 002-4AA21-1@@0 4) £ 25 m (82 ft) for handwheel signals 6FX8 002-4AA21-1@@0 4) PLC inputs £ 25 m (82 ft) for handwheel signals Distributor 4-wire acknowledgement 6FX2 006 - 1BH01 Programming device incl.cable Machine control panel 3) PP 031-MC pushbutton panel 3) PP 72/48 I/O module 4 high-speed digital CNC inputs/outputs each Probes, max. 2 Electronic handwheel, max. 2 PROFIBUS DP connection, e.g. SIMODRIVE 611 universal or SIMODRIVE POSMO 1) See PCU 50/PCU 70 2) HT 6 always connected: max. 200 m (650 ft) from plug X111 to HT 6 HT 6 not always connected: max. 200 m (650 ft) from plug X111 to HT 6 only with RS 485 repeater (6ES7 972-0AA01-1XA0). Otherwise, total MPI length from plug X111 to distributor £ 5 m (16.4 ft). The HT 6 must always be connected to one end of the MPI length (integrated bus connection). 3) Machine control panel and pushbutton panel can be operated together. 4) With DU box connector. 5) Use SINUMERIK 840Di with PCU 70 available soon.. 6) PROFIBUS cable see page A/4 7) The maximum cable length depants on current consumption, supply voltage and frequencie of the encoder (see manual SIMUMERIK 840Di). Please observe maximum permissible cable lengths (e.g. ≤ 50 m). If greater cable lengths are used, system malfunctions may occur. The order number code for cable variant 6FX@ ..., the general length key (-1@@@), and recommended lengths can be found on the foldout pages. Connection kit 6FX2 006 - 1BG00 Distributor 6FX2 006 - 1BC01 6FX2 006 - 1BF00 MPI cable see page A/1 EMERGENCY STOP/ acknowledge circuit 6FX2 002-1AA23-1@@0 £ 40 m ADI4 X2 X1 X3 X4/X5 X6-1 Dig. outputs X6-2 Dig. inputs Supplied with handheld unit 6FX2 002 - 3AD01 - 1@@0 £ 35 m 6FX8 002 - 2CD01 - 1@@0 7) 6FX5 002 - 2CD24 - 1@@0 7) 6FX8 002 - 2CC11 - 1@@0 7) EMERGENCY STOP/ acknowledge circuit Supplied with handheld unit EMERGENCY STOP/ acknowledge circuit Wire 1.0 mm2 to 2.5 mm2 Plug: MSTB 2,5/3-ST-5.08 Fa. Phoenix 6FX8 002 - 2CE02 - 1@@0 £ 35 m 6FX 8002 - 2CJ00 - 1@@0 £ 50 m Plug: FK-MCP 1,5/15-ST-3.81 Fa. Phoenix Wire 0.14 mm2 to 2.5 mm2 £ 30 m Mini handheld unit Handheld unit type B-MPI Handheld terminal HT 6 2) external power supply 24 V DC SIMODRIVE 611 analog 4 setpoints Incremental encoder with RS 422 (TTL) (5V) 6FX2 001-2... Incremental encoder with RS 422 (TTL) (24 V) 6FX2 001-2... Absolute encoder with SSI 6FX2 001-5... Pulse encoder ROD 320 in 1FT5-Motor SIMODRIVE 611 analog control plug-in unit for 1FK6 motor with resolver 24 V DC external power supply Sensors 1-n Actuators 1-n G_NC02_en_00038

SINUMERIK 840D NCU5.. X102 X112 X111 Link module 3) 6FC5 212- 0AA01- 1AA0 X130A X172 PROFIBUS DP cable see page A/4 6ES7 368-3@@@1-0AA0 6ES7 368-3@@@1-0AA0 6ES7 368-3@@@1-0AA0 6SN1 161-1CA00-0@A0 1) SIMATIC S7 IM361R S7-300 I/O IM 361 or second DSB oder EFP 6ES7 368-3@@@1-0AA0 OUT 6XV1 830-@@H10 see page A/4 Unit bus supplied with the unit 6FX2 002-1CA01-1@@0 4) SIMODRIVE 611 digital drive bus NCU Terminal block with terminator Pre-assembled Cables Overview of Connection Diagrams Please observe maximum permissible cable lengths (e.g. ≤ 50 m). If greater cable lengths are used, system malfunctions may occur. The order number code for cable variant 6FX@ ..., the general length key (-1@@@), and recommended lengths can be found on the foldout pages. IN £ 10 m 6FX2 002-1CA01-1@@0 4) £ 10 m 1) For lengths see Catalog NC 60 section 9 »Power modules«. 2) see Catalog part 4. 3) Only for NCU 573.2/573.3 and NCU 573.4. 4) The maximum connection length on the drive bus is 10 m (32 ft. 10 in.). 5) The cable 6FC5411-0AA80-0AA0 is aviable with a single-tier design with EFP. PROFIBUS-DP connection NCU Terminal block with terminator SIMODRIVE 611 digital unit bus Distribution Board DSB SINUMERIK 840D second NCU with link module IM 361 or second EFP 5) or DSB 6SN1 161-1CA00-0AA0 only 0,05 m MMC 103 Linkinterface 6FX8 002-1DA01-1@@0 £ 50 m 6FX5 002-1DB01-1@@0 £ 25 m Siemens NC Z · 2002/2003 SINUMERIK 840D X3 in 6ES7 368-3@@@1-0AA0 X3out Terminal strip 6FC9 340- X405 converter 8XY00-1@@0 2) 0.5 A 32I 34-pin PCI/ISA-adapter Probe SP2-1 Terminal strip converter 2) 0.5 A Terminal strip converter 2) 0.5 A In scope of supply of NCU box 6FC9 340- 8XY00-1@@0 6FC9 340- 8XY00-1@@0 Compact peripherals (EFP) X404 32I 34-pin X402 32O 34-pin Digitalization unit X341 X422 X411 X151 G_NC02_en_00039 2/25 2

SINUMERIK<br />

840D<br />

NCU5.. X102<br />

X112<br />

X111<br />

Link<br />

module 3)<br />

6FC5<br />

212-<br />

0AA01-<br />

1AA0<br />

X130A<br />

X172<br />

PROFIBUS DP cable<br />

see page A/4<br />

6ES7 368-3@@@1-0AA0<br />

6ES7 368-3@@@1-0AA0<br />

6ES7 368-3@@@1-0AA0<br />

6SN1 161-1CA00-0@A0 1)<br />

SIMATIC S7<br />

IM361R<br />

S7-300<br />

I/O<br />

IM 361<br />

or second<br />

DSB oder EFP<br />

6ES7 368-3@@@1-0AA0<br />

OUT<br />

6XV1 830-@@H10 see page A/4<br />

Unit bus supplied<br />

with the unit<br />

6FX2 002-1CA01-1@@0 4)<br />

SIMODRIVE 611<br />

digital<br />

drive bus<br />

NCU<br />

Terminal block<br />

with terminator<br />

<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />

Overview of Connection Diagrams<br />

Please observe maximum permissible cable lengths (e.g. ≤ 50 m). If greater cable lengths are used, system malfunctions may occur.<br />

The order number code for cable variant 6FX@ ..., the general length key (-1@@@), and recommended lengths can be found on the<br />

foldout pages.<br />

IN<br />

£ 10 m<br />

6FX2 002-1CA01-1@@0 4) £ 10 m<br />

1) For lengths see Catalog NC 60 section 9 »Power modules«.<br />

2) see Catalog part 4.<br />

3) Only for NCU 573.2/573.3 and NCU 573.4.<br />

4) The maximum connection length on the drive bus is 10 m<br />

(32 ft. 10 in.).<br />

5) The cable 6FC5411-0AA80-0AA0 is aviable with a single-tier<br />

design with EFP.<br />

PROFIBUS-DP<br />

connection<br />

NCU<br />

Terminal block<br />

with terminator<br />

SIMODRIVE 611<br />

digital<br />

unit bus<br />

Distribution<br />

Board DSB<br />

SINUMERIK<br />

840D<br />

second NCU<br />

with link module<br />

IM 361<br />

or second<br />

EFP 5) or DSB<br />

6SN1 161-1CA00-0AA0<br />

only 0,05 m<br />

MMC 103<br />

Linkinterface<br />

6FX8 002-1DA01-1@@0<br />

£ 50 m<br />

6FX5 002-1DB01-1@@0<br />

£ 25 m<br />

Siemens NC Z · 2002/2003<br />

SINUMERIK 840D<br />

X3 in<br />

6ES7 368-3@@@1-0AA0 X3out<br />

Terminal strip 6FC9 340- X405<br />

converter<br />

8XY00-1@@0<br />

2) 0.5 A 32I 34-pin<br />

PCI/I<strong>SA</strong>-adapter<br />

Probe SP2-1<br />

Terminal strip<br />

converter 2) 0.5 A<br />

Terminal strip<br />

converter 2) 0.5 A<br />

In scope of supply of NCU box<br />

6FC9 340-<br />

8XY00-1@@0<br />

6FC9 340-<br />

8XY00-1@@0<br />

Compact<br />

peripherals<br />

(EFP)<br />

X404<br />

32I 34-pin<br />

X402<br />

32O 34-pin<br />

Digitalization<br />

unit<br />

X341<br />

X422<br />

X411<br />

X151<br />

G_NC02_en_00039<br />

2/25<br />

2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!