Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Interface-DMP<br />
Interface<br />
CP 1476 MAP<br />
16-bit<br />
interface<br />
CP 231 A<br />
transceiver<br />
X121<br />
X131<br />
X121<br />
X111<br />
X121<br />
X111 6FC9 344-<br />
X121<br />
3SY00-1@@0<br />
X131<br />
X141<br />
See Catalog IK PI<br />
6ES5 727-1@@@0<br />
£ 50 m<br />
6ES5 721-0@@@0<br />
£ 25 m<br />
6FC9 344-4RY00-1@@0<br />
£ 10 m<br />
6ES5 727-1@@@0<br />
£ 50 m<br />
or<br />
6FC9 344-<br />
3SY00-1@@0<br />
or<br />
6FC9 344-<br />
3SY00-1@@0<br />
PG 740/PG 750<br />
programming<br />
device<br />
Industrial Ethernet<br />
bus system<br />
EG 185U<br />
extension unit<br />
PG 740/PG 750<br />
programming<br />
device<br />
Industrial Ethernet<br />
bus system<br />
DMP compact<br />
terminal block<br />
Distribution box 2)<br />
for handheld controller<br />
6FC5 147-0AA05-0AA0<br />
6FC9 344-4GY00-1@@0<br />
<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />
Overview of Connection Diagrams<br />
SINUMERIK 840C operator panels<br />
6FC9 344-<br />
3QY00-1@@0<br />
DMP terminating connector 1)<br />
Distributor<br />
handheld unit type A-MPC<br />
2) for<br />
6FX2 006-1BC01<br />
Active serial<br />
interfaces<br />
6FX8 002-4AA21-1@@04)<br />
6FX8 002-4AA21-1@@04)<br />
6FX8 002-4AA21-1@@0 4)<br />
6FX8 002-4AA21-1@@04)<br />
6FX8 002-4AA41-1@@04)<br />
Please observe maximum permissible cable lengths (e.g. ≤ 50 m). If greater cable lengths are used, system malfunctions may occur.<br />
The order number code for cable variant 6FX@ ..., the general length key (-1@@@), and recommended lengths can be found on the<br />
foldout pages.<br />
X111<br />
X121<br />
Central<br />
service<br />
board<br />
X121<br />
X112<br />
X122<br />
X132<br />
X111<br />
Cable on HHU<br />
Length 3 m 3)<br />
6FC9 344-4RY00-1@@0<br />
£ 10 m<br />
£ 25 m<br />
£ 25 m<br />
£ 25 m<br />
DMP compact<br />
terminal block<br />
6FC9 344-3QY00-1@@0<br />
DMP compact<br />
terminal block<br />
DMP terminating connector 1)<br />
Cable on HHU<br />
Length 3.5m/10 m 3)<br />
Cable<br />
distributor<br />
NC-Ready<br />
Fan-monitoring<br />
1) A maximum of 16 DMP terminal blocks can be connected to the RS 485 interfaces X111/X121 and X131/141.<br />
Up to 8 DMP compact terminal blocks can be connected to an RS 485 interface pair X111/X121 or X131/141.<br />
2) The maximum cable length at the RS 485 interfaces is 50 m per interface (X111; X121).<br />
3) Maximum permissible length between handwheel and NC = 25 m.<br />
4) NC side: DU box, I/O: open wire ends.<br />
DMP terminating connector 1)<br />
Cable distributor on<br />
central service board 3)<br />
Handheld unit (HHU) 3)<br />
Cable distributor on<br />
central service board 3)<br />
Handheld unit type<br />
A-MPC 3)<br />
RS 232 C/TTY<br />
PG 750<br />
programming<br />
device<br />
RS 232 C/TTY<br />
Distribution box<br />
handheld unit<br />
or<br />
Distributor 3)<br />
handheld unit<br />
type A-MPC<br />
Electronic<br />
handwheel<br />
Probe<br />
Siemens NC Z · 2002/2003<br />
3)<br />
3)<br />
G_NC02_en_00024<br />
2/21<br />
2