2<br />

<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />

Overview of Connection Diagrams<br />

SINUMERIK 840C<br />

PLC-CPU 135WD<br />

X111<br />

MMC-CPU<br />

X111<br />

X121<br />

X131<br />

1) Connecting cable is only required with the "STEP 5 package" option (Order number for 0.5 m length: 6FC9 340-8WY00-1AA5).<br />

2) With terminating connector 6FX2 003-0DA00.<br />

3) Not for new applications.<br />

Please observe maximum permissible cable lengths (e.g. ≤ 50 m). If greater cable lengths are used, system malfunctions may occur.<br />

The order number code for cable variant 6FX@ ..., the general length key (-1@@@), and recommended lengths can be found on the<br />

foldout pages.<br />

2/18<br />

X121/X131<br />

X141<br />

X122<br />

X151<br />

X141<br />

£ 50 m<br />

£ 50 m<br />

6FC9 344-4TY00-1@@0<br />

5 m<br />

or<br />

6FC9 340-8WY00-1@@0 1)<br />

0.5 m<br />

Siemens NC Z · 2002/2003<br />

<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />

6FC9 344-4RY00-1@@0 £ 10 m (depending on the connected device)<br />

6FC9 344-2PY00-1@@0<br />

6FC9 344-3SY00-<br />

1@@0<br />

or<br />

6FC9 344-3SY00-<br />

1@@0<br />

or<br />

6FC9 344-3SY00-<br />

1@@0<br />

6FC9 344-4NY01-1@@0<br />

6FX2 002-4AA31-1@@0<br />

6FC9 340-8WY00-1@@0<br />

6FX2 002-1AA02-1AD0<br />

6FC9 344-4XN00<br />

3 m<br />

PG/PC<br />

(PC-Link)<br />

6FC9 344-4GY00-1@@0 3)<br />

£ 10 m<br />

PLC-CPU 135WD<br />

X111<br />

DG2/DG4<br />

Keyboard interface 2)<br />

or<br />

operator panel interface 2)<br />

or<br />

DMP compact<br />

terminal block<br />

PG/PC<br />

(WS800A/PCIN)<br />

Distribution box 2) for handheld<br />

controller 6FC5 147-0AA05-0AA0<br />

Distributor 2) for handheld unit<br />

type A-MPC 6FX2 006-1BC01<br />

Streamer 3)<br />

Valitek PST2-M1200<br />

NC-CPU<br />

6FC9 344-3QY00-<br />

1@@0<br />

6FX8 002-4AA21-1@@0 3) 4)<br />

£ 35 m<br />

£ 35 m<br />

6FC9 344-5GY00-1@@0<br />

£ 50 m<br />

3 m 3)<br />

6FX8 002-4AA21-1@@0 3) 4)<br />

Interface<br />

MMC<br />

X121<br />

X111<br />

X131<br />

X111<br />

cable at HHU<br />

cable at HHU 3)<br />

length 3.5 m/10 m<br />

1) Up to 15 DMP terminal blocks can be connected to the RS 485 interfaces (X121/X131).<br />

2) The operator panel and keyboard interface or the distribution box are treated like a DMP terminal block and<br />

can be connected to the DMP block.<br />

The maximum cable length to the RS 485 interfaces is 50 m per interface (X121, X131).<br />

3) The distance between hand-held unit and cable distributor on CSB must not exceed 25 m.<br />

4) DU box connector, open wire end.<br />

5) Open wire ends.<br />

or<br />

CRT<br />

RGB connection<br />

Operator panel<br />

or<br />

RS 232 C<br />

keyboard interface<br />

DMP terminating connector 1)<br />

DMP terminating connector 1)<br />

PCMCIAcard<br />

Typ II<br />

6FX2 002-1CB01-1@@0 2)<br />

£ 10 m<br />

5)<br />

Programming device<br />

DMP compact<br />

terminal block<br />

6FC9 344-3QY00-1@@0<br />

DMP compact<br />

terminal block<br />

DMP terminating connector 1)<br />

or<br />

Cable distributor on<br />

central service board<br />

Handheld unit controller<br />

(HHU)<br />

Cable distributor on<br />

central service board<br />

Handheld unit<br />

type A-MPC<br />

8 fast interrupt inputs<br />

PCMCIAcard<br />

Typ III<br />

Interface<br />

RS 232 C<br />

FD-E2<br />

floppy drive<br />

SIMODRIVE 611<br />

digital interface<br />

G_NC02_en_00021