Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
2<br />
<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />
Overview of Connection Diagrams<br />
SINUMERIK 840C<br />
PLC-CPU 135WD<br />
X111<br />
MMC-CPU<br />
X111<br />
X121<br />
X131<br />
1) Connecting cable is only required with the "STEP 5 package" option (Order number for 0.5 m length: 6FC9 340-8WY00-1AA5).<br />
2) With terminating connector 6FX2 003-0DA00.<br />
3) Not for new applications.<br />
Please observe maximum permissible cable lengths (e.g. ≤ 50 m). If greater cable lengths are used, system malfunctions may occur.<br />
The order number code for cable variant 6FX@ ..., the general length key (-1@@@), and recommended lengths can be found on the<br />
foldout pages.<br />
2/18<br />
X121/X131<br />
X141<br />
X122<br />
X151<br />
X141<br />
£ 50 m<br />
£ 50 m<br />
6FC9 344-4TY00-1@@0<br />
5 m<br />
or<br />
6FC9 340-8WY00-1@@0 1)<br />
0.5 m<br />
Siemens NC Z · 2002/2003<br />
<strong>Pre</strong>-<strong>assembled</strong> <strong>Cables</strong><br />
6FC9 344-4RY00-1@@0 £ 10 m (depending on the connected device)<br />
6FC9 344-2PY00-1@@0<br />
6FC9 344-3SY00-<br />
1@@0<br />
or<br />
6FC9 344-3SY00-<br />
1@@0<br />
or<br />
6FC9 344-3SY00-<br />
1@@0<br />
6FC9 344-4NY01-1@@0<br />
6FX2 002-4AA31-1@@0<br />
6FC9 340-8WY00-1@@0<br />
6FX2 002-1AA02-1AD0<br />
6FC9 344-4XN00<br />
3 m<br />
PG/PC<br />
(PC-Link)<br />
6FC9 344-4GY00-1@@0 3)<br />
£ 10 m<br />
PLC-CPU 135WD<br />
X111<br />
DG2/DG4<br />
Keyboard interface 2)<br />
or<br />
operator panel interface 2)<br />
or<br />
DMP compact<br />
terminal block<br />
PG/PC<br />
(WS800A/PCIN)<br />
Distribution box 2) for handheld<br />
controller 6FC5 147-0AA05-0AA0<br />
Distributor 2) for handheld unit<br />
type A-MPC 6FX2 006-1BC01<br />
Streamer 3)<br />
Valitek PST2-M1200<br />
NC-CPU<br />
6FC9 344-3QY00-<br />
1@@0<br />
6FX8 002-4AA21-1@@0 3) 4)<br />
£ 35 m<br />
£ 35 m<br />
6FC9 344-5GY00-1@@0<br />
£ 50 m<br />
3 m 3)<br />
6FX8 002-4AA21-1@@0 3) 4)<br />
Interface<br />
MMC<br />
X121<br />
X111<br />
X131<br />
X111<br />
cable at HHU<br />
cable at HHU 3)<br />
length 3.5 m/10 m<br />
1) Up to 15 DMP terminal blocks can be connected to the RS 485 interfaces (X121/X131).<br />
2) The operator panel and keyboard interface or the distribution box are treated like a DMP terminal block and<br />
can be connected to the DMP block.<br />
The maximum cable length to the RS 485 interfaces is 50 m per interface (X121, X131).<br />
3) The distance between hand-held unit and cable distributor on CSB must not exceed 25 m.<br />
4) DU box connector, open wire end.<br />
5) Open wire ends.<br />
or<br />
CRT<br />
RGB connection<br />
Operator panel<br />
or<br />
RS 232 C<br />
keyboard interface<br />
DMP terminating connector 1)<br />
DMP terminating connector 1)<br />
PCMCIAcard<br />
Typ II<br />
6FX2 002-1CB01-1@@0 2)<br />
£ 10 m<br />
5)<br />
Programming device<br />
DMP compact<br />
terminal block<br />
6FC9 344-3QY00-1@@0<br />
DMP compact<br />
terminal block<br />
DMP terminating connector 1)<br />
or<br />
Cable distributor on<br />
central service board<br />
Handheld unit controller<br />
(HHU)<br />
Cable distributor on<br />
central service board<br />
Handheld unit<br />
type A-MPC<br />
8 fast interrupt inputs<br />
PCMCIAcard<br />
Typ III<br />
Interface<br />
RS 232 C<br />
FD-E2<br />
floppy drive<br />
SIMODRIVE 611<br />
digital interface<br />
G_NC02_en_00021