PM024-094R07102 Schakontv.indd - Niko
PM024-094R07102 Schakontv.indd - Niko PM024-094R07102 Schakontv.indd - Niko
05-351 / 05-352 / 05-336 / 05-300 4. TECHNICAL DATA 4.1. Easywave modular receiver 1 channel 05-351 • 1 potentialfree relay contact, two-way switch, suitable only for monophase configurations 10A*, for the N.O. contact. The N.C. contact can interrupt max. 4A, 230V 50Hz. The relay contacts cannot be used in SELV circuits. * Expected life in normal conditions, for ohmic loads: 40.000 switching operations at 10A; >40.000 switching operations at 8A. •supply voltage 230V 50Hz • DIN rail mounting only, width 72mm, 4U • degree of protection IP20 •can be used with all Easywave transmitters • LED and local push button (select) with on/off function • up to 32 transmitters can be allocated to 1 receiver • to each transmitter, a different function can be allocated • wiring diagram fig.1 56 EN
05-351 / 05-352 / 05-336 / 05-300 LOAD TABLE for 05-351 Type of load Resistive: incandescent Symbol Max. load 230V 50Hz lamps, halogens 230V… Inductive: Low-voltage lighting via ferromagnetic transformers 10A 2300W (transformer load = minimum 85%) Non- or series compensated fluorescent lighting 2,6A 600VA with ferromagnetic ballasts Parallel compensated fluorescent lighting 10A 2300VA with ferromagnetic ballasts ECG: electronic control gear (HF fluorescent loads, 2,6A 600W electronic transformers…) 4A 920VA EN 57
- Page 6 and 7: 05-351 / 05-352 / 05-336 / 05-300 2
- Page 8 and 9: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 10 and 11: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 12 and 13: 05-351 / 05-352 / 05-336 / 05-300 5
- Page 14 and 15: 05-351 / 05-352 / 05-336 / 05-300 5
- Page 16 and 17: 05-351 / 05-352 / 05-336 / 05-300 3
- Page 18 and 19: 05-351 / 05-352 / 05-336 / 05-300 6
- Page 20 and 21: 05-351 / 05-352 / 05-336 / 05-300 S
- Page 22 and 23: 05-351 / 05-352 / 05-336 / 05-300 2
- Page 24 and 25: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 26 and 27: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 28 and 29: 05-351 / 05-352 / 05-336 / 05-300 5
- Page 30 and 31: 05-351 / 05-352 / 05-336 / 05-300 2
- Page 32 and 33: 05-351 / 05-352 / 05-336 / 05-300 3
- Page 34 and 35: 05-351 / 05-352 / 05-336 / 05-300 6
- Page 36 and 37: 05-351 / 05-352 / 05-336 / 05-300 I
- Page 38 and 39: 05-351 / 05-352 / 05-336 / 05-300 I
- Page 40 and 41: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 42 and 43: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 44 and 45: 05-351 / 05-352 / 05-336 / 05-300 5
- Page 46 and 47: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 48 and 49: 05-351 / 05-352 / 05-336 / 05-300 3
- Page 50 and 51: 05-351 / 05-352 / 05-336 / 05-300 6
- Page 52 and 53: 05-351 / 05-352 / 05-336 / 05-300 C
- Page 54 and 55: 05-351 / 05-352 / 05-336 / 05-300 2
- Page 58 and 59: 05-351 / 05-352 / 05-336 / 05-300 4
- Page 60 and 61: 05-351 / 05-352 / 05-336 / 05-300 5
- Page 62 and 63: 05-351 / 05-352 / 05-336 / 05-300 5
- Page 64 and 65: 05-351 / 05-352 / 05-336 / 05-300 3
- Page 66 and 67: 05-351 / 05-352 / 05-336 / 05-300 7
- Page 68 and 69: 05-351 / 05-352 / 05-336 / 05-300 F
- Page 70: 05-351 / 05-352 / 05-336 / 05-300 S
05-351 / 05-352 / 05-336 / 05-300<br />
4. TECHNICAL DATA<br />
4.1. Easywave modular receiver 1 channel 05-351<br />
• 1 potentialfree relay contact, two-way switch, suitable only for monophase configurations<br />
10A*, for the N.O. contact. The N.C. contact can interrupt max. 4A, 230V 50Hz. The relay<br />
contacts cannot be used in SELV circuits.<br />
* Expected life in normal conditions, for ohmic loads: 40.000 switching operations at 10A;<br />
>40.000 switching operations at 8A.<br />
•supply voltage 230V 50Hz<br />
• DIN rail mounting only, width 72mm, 4U<br />
• degree of protection IP20<br />
•can be used with all Easywave transmitters<br />
• LED and local push button (select) with on/off function<br />
• up to 32 transmitters can be allocated to 1 receiver<br />
• to each transmitter, a different function can be allocated<br />
• wiring diagram fig.1<br />