65-411<br />
The dimmer has two additional ‘bus info’ LEDs (see fig. 1) that give information about the status<br />
of the DALI bus.<br />
The ‘activity’ LED blinks when there is activity on the DALI bus.<br />
The ‘bus error’ LED blinks if the dimmer no longer is connected correctly to the DALI bus or if<br />
there is a fault on the DALI bus.<br />
6. WARNINGS WITH RESPECT TO OPERATION<br />
- This appliance is not suitable for the control of motors.<br />
- When using a ferromagnetic transformer, check whether it is suitable for use in combination<br />
with an electronic control.<br />
- When using halogen lighting with wire-wound transformers, the efficiency of the transformers<br />
must be taken into account. Load the transformers to at least 80% of their nominal power.<br />
Take into account the efficiency of the transformer when calculating the total dimmer load. The<br />
transformer must be suitable for dimming.<br />
- Electronic transformers may behave unstably if the wire length between the transformer and<br />
the lamps exceeds 2m.<br />
- This dimmer produces a limited amount of heat under normal operating conditions. Allow for<br />
sufficient heat dissipation; do not cover the dimmer with insulating material. Take into account<br />
the maximum power when installing several dimmers on top of, or alongside each other. Install<br />
a fan, if necessary.<br />
- When installing several dimmers on top of, or alongside each other, it may be necessary to<br />
reduce the maximum power (see load table).<br />
- When installing the dimmer near an audio system, it is advisable to use shielded wires to<br />
interconnect the various system components.<br />
- Lamps connected via dimmers do not produce the maximum light intensity. Their light output<br />
will always be less than an identical lamp connected directly to the mains.<br />
- The dimmer is provided with a “PLC” filter. This filter ensures that any interference caused by<br />
signals transmitted over the mains is suppressed as much as possible.<br />
- Do not switch on the dimmer if the transformers are not loaded.<br />