12.10.2020 Views

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1-66 | Melters

VersaBlue Adhesive Melters

Models V12, V25, V50, and V100 Liter

VersaBlue Melter Configuration

BASE MELTER

OPTIONS

Melter Type

Melter Capacity

Voltage

Pump 1

Pump 2

Reserved

Hose/Applicator

Pairs

Flow Control

Inter. Pressure

Indication

Level Control

Ligjt Tower

Main Switch

Host

Communication

Key-to-Linet

Casters

Inert Gas

Filter and Safety

Valve

N/A

Boxes

1–2

Boxes

3–5

- X \ X X X

Box

6

Box

7

Box

8

Box

9

Boxes

10–11

Box

12

Box

13

Box

14

Box

15

Box

16

Box

17

Box

18

Box

19

Box

20

Box

21

Box

22

Box

23

Boxes

24–26

Box

1–2

Box

3–5

Melter Type

Description

Standard Ni-120, 40–230 °C (100–450 °F)

High-Temp., PT100, 40–250 °C (100–480 °F)

Code

VA

VT

Melter Capacity

Description

Code

12 L — 11.6 kg (25.3 lb) 012

25 L — 24.3 kg (53.4 lb) 025

50 L — 48.5 kg (107 lb) 050

100 L — 97 kg (213 lb) 100

Box

8–9

Pumps (1)

Description

Code

SN0030 — 1.4 kg/hr (3.1 lb/hr)

A

SN0046 — 2.2 kg/hr (4.9 lb/hr)

SN0062 — 2.9 kg/hr (6.5 lb/hr)

C

SN0093 — 4.5 kg/hr (9.8 lb/hr)

D

SN0186 — 8.9 kg/hr (19.6 lb/hr)

E

SN0371 — 17.8 kg/hr (39.2 lb/hr)

F

SN0073 — 37.1 kg/hr (81.6 lb/hr)

G

SN1710 — 82.1 kg/hr (180 lb/hr)(2)

H

SH0371 — 17.8 kg/hr (39.2 lb/hr) (hardened) 9

SH0773 — 37.1 kg/hr (81.6 lb/hr) (hardened) Z

None

X

Box

7

Voltage

Description

Code

200–240V 1-phase 50/60 Hz (V12 only) 1

200V 3-phase 50/60 Hz

(integrated transformer)

2

200–240V 3-phase 50/60 Hz 3

380–415V-Y 3-phase 50/60 Hz 4

400V 3-phase 50/60 Hz

(integrated transformer)

5

480V 3-phase 50/60 Hz

(integrated transformer)

6

Box

12

Box

14

Hose/Applicator Pairs

Description

Code

2 Hose/Applicator Pairs 2

4 Hose/Applicator Pairs (3-phase only) 4

6 Hose/Applicator Pairs (3-phase only) 6

8 Hose/Applicator Pairs (100 L only) 8

Flow Control (3)

Description

Automatic Pneumatic Pressure Control,

KBV flow control

Manual Pneumatic Pressure Control, KBV

flow control

Flow Control Bypass

Output Pressure Control, KBV flow control,

requires IPI option, Box 15

Pressure build-up (APC), requires IPI

option, Box 15

None

Code

P

M

F

C

E

X

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.