1-58 | Melters

VersaBlue Plus Series Adhesive Melters

Models 25, 50, and 100 Liter

Specifications

Item

V25

Configuration VB/VW VC/VX VD/VY VE/VZ

Reservoir type

Release-coated grid and reservoir

Pump type

Spur gear pump with variable AC motor

Tank volume L (in 3 ) 25 (1526)

Holding capacity kg (lb) 23.8 (53.4)

Pump rate kg/hr (lb/hr) (1) (2) 1.4–82.1 (3–181)

Filter type

Saturn ® basket-style filter

Melt rate kg/hr (lb/hr) 25 (55)

Throughput kg/hr (lb/hr) 37 (81.4)

Max. hydraulic pressure

85 bar/ 8.5 MPa (1230 psi)

Max. number of pumps

Up to 4 single stream OR 4 dual stream

Number of hose/applicator capacity 2, 4, 6, or 8

Maximum system power capacity:

2 hoses/applicators

4 hoses/applicators

6 hoses/applicators

8 hoses/applicators

Electrical service (3) 50/60 Hz (V)

Input/Output capability

TruFlow control

Closed-loop pattern control

Module response monitoring

External metering devices

Maximum pressure sensors (4)

Melter dimensions W x H x D mm (in.)

Installation dimensions W x H x D mm (in.)

10280 watts

13880 watts

17480 watts

21080 watts

3/PE AC 2005

3/PE AC 200–240

3/N/PE AC 380–415 Y

3/PE AC 4005

3/PE AC 4805

9 outputs/13 inputs

Up to 4 channels

Up to 8 channels

Up to 32 channels

Up to 4 combined internal & external controllers

8 internal

1100 x 1382 x 1035 (43.3 x 54.4 x 40.8)

2699 x 1205 x 1281 106.3 x 61.6 x 50.4)

Weight (5) , empty kg (lb) 265 (584)

Ambient temperature range

0 to 40 °C (32 to 104 °F)

Operating temperature range

40 to 230 °C (100 to 450 °F)

Temperature control stability

± 1 °C (2 °F)

Enclosure rating

IP54

Approvals

CE, UL

(1)

Actual rates will vary depending on adhesive type, application

parameters and input voltage.

(2)

Range given is for maximum pump rate of various pumps available.

(3)

Permitted deviation from rated line voltage is ±10%.

(4)

Up to 8 external sensors optional.

(5)

Weight depends on melter configuraton.

(6)

With integrated transformer, use 240V applicators and hoses.

Casters optional; PROFIBUS, PROFINET, ControlNet, and Ethernet I/P

optional.

PROFIBUS and PROFINET are registered trademarks of PROFIBUS &

PROFINET International. ControlNet and ControlLogix are registered

trademarks of Rockwell Automation., Inc.