1-26 | Melters

ATS Retrofit Kit

External Flow Measuring and Process Control Device

Specifications

Item

Maximum system operating pressure

Specification

10 Mpa (1450 psi)

Instantaneous flow fate range 0.03–91 kg/hr (0.07–200.6 lb/hr) (assuming SG* = 1.0)

Displacement 1.0 cc/rev = 1 g/rev = 0.001 kg/rev = 0.0022 lb/rev (assuming SG* = 1.0)

Resolution 0.025 cc (25 mg) or (0.055 lb) (assuming SG* = 1.0)

Viscosity range

Output signals

ATS retrofit manifold electrical

requirements

ATS control box power supply electrical

requirements

600–10,000 cps

2 (Enabled Output and Alarm Output)

24 VDC sourcing (PNP)

25 mA each

Number of hose/applicator channels required: 1

Heater power: 350 W

200 mA (maximum)

24 VDC +/-10%

Manifold construction Aluminum, type 6061-T6

Gears: 86L20 steel, case-hardened

Flow meter construction

Gear shafts: Carbon steel, hardened and grounded (DIN 6325, M6)

Body: 316 stainless steel

Inductance: 1 mH (+/-10%)

Flow meter sensors

Resistance: 15 ohm (+/-10%)

Frequency: 60 kHz (+/-10%)

Temperature rating

204 °C (400 °F) maximum

Working temperature range

-5–50 °C (23–122 °F)

ATS control box IP rating

IPX4

*SG = specific gravity

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.