Adhesive & Sealants Equipment Guide

Hand-Held Applicators | 9-15

Web Content

AD-31 Spray Hand-Held Applicators

Description

AD-31 spray hand-held applicators use compressed air to

atomize hot melt adhesive. Independent atomizing air and

pattern air control allows adjustment of pattern size, shape

and density.

Features

• Independent controls for atomizing and pattern air utilize one

standard spray nozzle that yields pattern widths ranging from

51 to 203 mm (2 to 8 in.).

• Micro-adjust feature alters material flow at the nozzle orifice.

• Two independently heated and controlled temperature

zones improve temperature stability to minimize the cooling

effect of expanding spray air. Each zone, located in the pivot

sleeve and in the nozzle section, contains a separate heater

and temperature sensor, allowing use of room temperature

compressed air.

• Depending on the applicator, hand-held applicators employ

either a preset thermostatic temperature sensor or a RTD

(resistance temperature detector) sensor. RTD sensing provides

temperature control precision by reducing temperature

fluctuations that negatively affect flow and cause char

formation.

• Hand-held applicators with RTD sensors require an extra

temperature control channel for the hand applicator nozzle

section. Cordsets that connect the control channel to the nozzle

section are available in different lengths to accommodate hose

length.

• A 260 °C (500 °F) overtemperature thermostat in the nozzle

section shuts off heater power in case of abnormally high

temperature conditions.

• A 190 °C (375 °F) thermostat is standard on thermostatically

controlled hand-held applicators. Optional thermostats for

different temperature settings are available for customer

installation.

• Distinctive ever-cool handle provides comfortable operation

and helps reduce risk of burns by containing heated

components and adhesive-flow paths within the hand

applicator body, not the handle. Impact resistant molded shell

extends service life.

• A 90° hose swivel permits ease of movement and limits hose

twisting.

• Hand-held applicators accommodate broad range of Nordson

melters.

AD-31 Spray Hand-Held Applicator

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.