12.10.2020 Views

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

6-4 | Extruder Systems

EEX Extruder Systems

Configuration

Extruder

Temperature Sensor

Flanged Pump Station

Pump MIDR

Hose Connection

Coding Device

Hopper Level Sensor

Standby-Temp.

Setback

Week/Day Timer

Hopper Protection

Grid

Casters

Protection Frame for

Sensors

Additional

Hose/Applicator

connections

Special Request

Box

1–6

Box

8

Box

9

Box

10

Box

11

Box

12

Box

13

Box

14

Box

15

Box

16

Box

17

Box

18

Box

19

Box

23

Boxes

1–6

Box

8

Extruder Size

Description

EEX Extruder 10 kg/hr

EEX Extruder 40 kg/hr

EEX Extruder 100 kg/hr

EEX Extruder 200 kg/hr

PT100

Typ NI120 (1)

(1)

Up to 200 °C.

Temperature Sensor

Description

Code

EEX010

EEX040

EEX100

EEX200

Code

P

N

Box

10

Pump MIDR

Description

Code

No pump selected

X

10 l/h max. per pump(1) (2) A

20 l/h max. per pump(1) (2) B

40 l/h max. per pump(1) (2) C

80 l/h max. per pump(1) (2) (3)

(EEX 100 /EEX 200 only)

D

160 l/h max. per pump(1) (2) (3)

(EEX 100 /EEX 200 only)

E

220 l/h max. per pump(1) (2) (3)

(EEX 200 only)

H

(1)

Pump selection only possible if pump station selected.

(2)

All pumps have to be same size.

Box

9

Flanged Pump Station

Description

Code

No pump station (pressure controlled) 0

Single pump station (1 pump) 1

Single pump station with recirculating

ports (1 out/1 in)*

2

Double pump station (2 pumps) 3

Double pump station with recirculating

ports (2 out/2 in)*

4

Quadruple pump station (4 pumps)

(not possible with EEX10)

5

*Only in combination with a recirculating applicator.

(3)

Pump D and E only possible up to 2-pump station.

Box

11

Box

12

Hose Connection

Description

Code

Hose connection 8 mm diameter 1

Hose connection 13 mm diameter 2

Hose connection 16 mm diameter 3

Hose connection 20 mm diameter 4

Hose connection 32 mm diameter 5

Cooling Device

Description

Code

No cooling device

X

Stand-alone cooling device*

(EEX 10 /EEX 40 only)

K

Cooling device on extruder frame*

(EEX 100 /EEX 200)

R

*Mandatory if customer does not supply cooling

water circuit.

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.

International Orders, call 1-440-985-4797, fax 1-440-985-1096, or email intcustomerservice@nordson.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!