2-18 | Foam Systems

FoamMelt Processors

200 Series

Features

• Enhanced system provides advanced controls, improved

serviceability and pinpoint temperature control.

• Utilizes a patented process to improve material

performance. The foaming process mixes inert gas with

the hot melt material for increased open times and

reduced material usage.

• The pressure control valve, the filter/density controller

and the drain valve are all front mounted to provide

easy access for maintenance.

• Advanced Vista control system improves productivity

by automating many operator functions.

• A density sensor located in the filter/density controller

automatically monitors and adjusts the gas/adhesive

mix.

Specifications

Item

Reservoir type

Holding capacity kg (lb), grid/reservoir/hopper 32 (70)

Specification

Melt rate (1) kg/hr (lb/hr) 46 (100)

Grid/reservoir and warm hopper

Pump type

Two-stage gear pump

Maximum pump rate kg/hr (lb/hr)

MCDR (2) MIDR (3)

25 (55) standard pump

34 (75) high output pump

Maximum pump speed rpm 900

Motor rating

AC variable-speed, 3 HP

Inert gas supply (industrial grade CO 2

or N 2

) kPa (psi) 207-345 (30-50)

Recommended operating air pressure (dry, filtered) kPa (psi) 620-830 (90-120)

Viscosity range centipoise 1,000-40,000

Type manifold

External circulating

Operating temperature ranges

38 - 205°C (100 - 400°F)

Hose ports (hydraulic)

4 (2 supply, 2 return)

Hose capacity (electric) 6

Applicator capacity (electric) 4

Electrical service

Amperage (maximum)

Voltage

Maximum system power capacity @ 230 VAC 15.0 kW (43 A)

Weight kg (lb) 130 (285)

Approvals and certifications

CE

(1)

Actual rate can vary depending on adhesive viscosity and other characteristics.

(2)

Maximum Continuous Delivery Rate @ 50% density reduction.

47 A

220-240 VAC, 50/60 Hz, 3Ø

400/230V, 50 Hz, 3/N/PE, 27 A

(3)

Maximum Instantaneous Delivery Rate @ 50% density reduction and 50% applicator duty cycle - 1.0 second.

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.

International Orders, call 1-440-985-4797, fax 1-440-985-1096, or email intcustomerservice@nordson.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!