12.10.2020 Views

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

Nordson's Adhesives & Sealants Guide - 2020-2021 (13th Edition)

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Adhesive & Sealants Equipment Guide

Melters | 1-81

VersaBlue XN and XC Series Adhesive Melters

VersaBlue XN Configuration (contd.)

Options

Return Hose

Flow

Control

Internal

Pressure

Indication

External

Pressure

Inputs

Digital

Pressure

Input

Auxiliary

Hose/Appl

Pairs

Auxiliary

Motor

Control

Auxiliary

Motor

Control Type

Voltage

I/O &

Indication

Reserved

Control

system

Air Run-up

Applicator

solenoid

Control

Sensor type

Heat

Exchanger/

ACM

1 X A X X A X X 4 D A A X G P X

Boxe

25

Box

26

Box

27

Box

28

Box

29

Box

30

Box

31

Box

32

Box

33

Box

34

Box

35

Box

36

Box

37

Box

38

Box

39

Box

40

Options

Box

25 Return Hose (1)

Description

Code

Tank 1 1

Tank 2 2

Tanks 1 & 2 3

None

(1) Includes 1 hose fitting and MPCV per return manifold.

Requires heating zone per manifold.

Box

26

Flow Control

Description

Auto flow cont. w/ min speed

Auto flow cont.

Pressure Build-up (1)

SV w/ Indication (no MPCV)

None (Standard MPCV)

(1) Requires IPI in box 21.

Box

27 Internal Pressure Indication (1)

Description

Post-filter pressure Indication

Pre-filter pressure Indication

Pre & Post filter pressureIndication

None

X

Code

T

B

N

O

X

Code

(1) Output pressure control is standard functionality when

pressure indication is selected.

Box

28

External Pressure Inputs

Description

A

G

H

X

Code

4 inputs F

8 inputs E

12 inputs (1) T

16 inputs (1) S

None

X

(1) Available only with twin tank and 200L configurations.

Box

29

Digital Pressure Input

Description

Code

4 Inputs F

8 Inputs E

12 Inputs T

None

X

Box

30

Box

31

Box

32

Auxiliary H/A Pairs (@ Elec. Panel)

Description

Code

2 H/A (Included in Base Unit) A

6 H/A B

10 H/A C

Auxiliary Motor Control (Qty)

Description

Code

Max. 6 #

None

Auxiliary Motor Control Type

Description

AC PowerFlex 40 (750W) (1)

Servo Ultra 3000 (1)

1x AC Lenze Vector 8200 (2)

None (Standard)

(1) Rockwell PLC only.

(2) Only with S7 control system (A in Box 36).

Box

33

Box

34

Box

35

Voltage

Description

X

Code

A

S

L

X

Code

200-240 3P ∆ (Red Main Switch, 3-Pole) 2

200-240 3P ∆ (Black Main Switch,

3-Pole)

380-415 Y (Red Main Switch, 4-Pole) 4

380-415 Y (Black Main Switch, 4-Pole) C

I/O & Indication

Description

Standard -XS2 (Discrete)

Warning Light Tower

WLT and Discrete I/O

None

Reserved

Reserved

Description

B

Code

D

W

K

X

Code

X

Box

36

Control System

Description

Siemens S7-300 w/ TP270

ControlLogix ENet ext. PView1000

ControlLogix CNet ext. PView1000

Box

37 Air Run-up (1)

Description

Code

A

F

T

Code

4 outputs 4

8 outputs 8

12 outputs 12

16 outputs 16

None

(1) Air run-up kit sold separately

Box

38

Box

39

Box

40

Std VersaBlue

Applicator Solenoid Control

Description

Pat. Cont. through GS conn.

None

PT100

Ni-120

Heat Exchanger

ACM Connectivity

Sensor Type

Description

Heat Exchanger/ACM

Description

Heat Exchanger and ACM

None

X

Code

G

P

X

Code

P

N

Code

E

A

B

X

To place your order, NAD call 1-888-NORDSON (1-888-667-3766), fax 1-770-497-3733 or online at www.enordson.com.

International Orders, call 1-440-985-4797, fax 1-440-985-1096, or email intcustomerservice@nordson.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!