13.9.3 Surface finish<br />

© 2007 MECON Limited<br />

All rights reserved<br />

<strong>General</strong> <strong>Technical</strong> <strong>Specification</strong><br />

Blown grade bitumen shall be conforming to IS : 702-1988 and residual grade bitumen<br />

conforming to IS:73 respectively. This shall be prepared by heating to correct working<br />

temperature.<br />

Pea sized gravel/grit 6mm and down.<br />

13.10 P.V.C. Membrane/Sheets<br />

13.10.1 Properties<br />

14.0 WATER BAR<br />

14.1 <strong>General</strong><br />

14.2 Jointing<br />

Membrane type water proofing either PVC or APP of reputed make like CICA,CICO<br />

shall only be used in this project and applied as per manufactures specifications<br />

Polyvinyl chloride sheets for the purpose of water proofing and other underground use<br />

are specially developed sheets made from the compounded resin of grade MP/DP/CR-02<br />

and shall be resistant to the passage of gross water and water vapour. It shall be<br />

corrosion resistant and resistant to a wide range of acidic and alkali reagents, saltpetre<br />

action, salt water and ultra violet rays etc. PVC sheets manufactured by approved and<br />

reputed firms like Maxlok Polymer <strong>Ltd</strong>. shall only be used<br />

The sheets shall consist of Knobs or Lugs jutting out of the sheets in a grid fashion so as<br />

to provide a perfect grip in the mortar and concrete. Sheet thickness, spacing of the<br />

knobs and their projection from the sheet shall be as specified in the item. The sheets<br />

shall be of maximum practicable length and width unless otherwise specified.<br />

The adhesive used for jointing shall be of approved quality and of grade C-02.<br />

The sample of the material shall be got approved before use.<br />

i) Chemical Composition : Resin Plasticiser Inhibitor Stabiliser<br />

UV Barrier.<br />

ii) Thickness<br />

: Not less than 0.25 mm<br />

iii) Rupture/Tensile Strength : Not less than 225Kg/cm2<br />

iv) Adhesive<br />

[width]<br />

bond Strength : : Not less than 7.1 Kg/cm<br />

v) Elongation at Break : 130%<br />

Water bar for use in construction/expansion joints in concrete and reinforced concrete<br />

structures shall be of copper sheet, galvanised steel sheet, rubber or PVC as shown in<br />

drawing or described in the Schedule of Items. It shall be subject to approval of Engineer.<br />