<strong>General</strong> <strong>Technical</strong> <strong>Specification</strong><br />
Plain transparent glass for glazing and framing shall conform to IS: 2835-1987. It shall be<br />
free from flaws, specks, bubbles or distortions.<br />
11.3 Ground and Frosted Glass<br />
11.4 Thickness<br />
11.5 Inspection<br />
12.0 PAINTS<br />
12.1 <strong>General</strong><br />
Glare reducing or heat absorbing glass shall be "Calorex" or approved equivalent and<br />
special care shall be taken to grind smooth and round off the edges before fixing.<br />
Glass shall have the following thickness, unless otherwise stated in the Schedule of<br />
Items or drawings<br />
Upto 60 cms x 60 cms ... 3 mm<br />
do- of larger size ... 4 mm and 4.8mm<br />
Sheet glass for doors ... 5.5 mm<br />
Rough cast wired ... 6.4 +/- 0.4 mm<br />
All glasses shall be subject to inspection on the site. Glass found to suffer from defects<br />
shall be rejected. Samples submitted for inspection shall be selected so as to be<br />
representative of the consignment.<br />
All paints, varnishes, distemper or other surface coating materials shall be of approved<br />
quality conforming to the appropriate <strong>India</strong>n Standard, wherever such standard is<br />
available, and be obtained from a manufacturer of repute. If there is more than one<br />
quality for one particular product, only first quality shall be used unless otherwise stated in<br />
the Schedule of Items.<br />
12.2 Sampling and Testing<br />
12.3 Storage<br />
The Engineer may, at his discretion, require samples of paint to be tested. In such cases<br />
testing will be according to IS : 101 (Part 1 to 8) -1964 to 1993.<br />
Paints, primers, distempers and varnishes shall be delivered in sealed containers. They<br />
shall be stored in cool dry condition to the satisfaction of the Engineer.<br />
12.4 Paints for Priming<br />
Ready mixed paints for priming coats of steel and iron work shall either comply with IS :<br />
2074-1992 "Ready Mixed Paint", "Red Oxide Zinc Chrome Priming" or Red Oxide metal<br />
primer as specified. For wood work it shall be pink/white wood primer as specified by the<br />
manufacturer of the synthetic enamel paints, conforming to IS : 3536-1966.<br />
12.5 Paints for finishing<br />
Ready mixed oil synthetic enamel paint of approved manufacturers like Berger, Jenson &<br />
Nicholson, Shalimar, I.C.I., Asian, Garware and Goodlass Nerolac paints only shall be<br />
Civil<br />
Page 21 of 42<br />
GS-07