Zenitel Communication On Board 2020
Brochure voor Zenitel - Vingtor Stentofon - Phontech en STC producten van Theunissen Technical Trading. Meer info: b.derks@tttbv.com
Brochure voor Zenitel - Vingtor Stentofon - Phontech en STC producten van Theunissen Technical Trading. Meer info: b.derks@tttbv.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
FLOWIRE
The Flowire Converter enables
Ethernet to run on the same two
wires as power, enabling simpler
cabling and opens up for longer
cable hauls.
1008080110
FCDC1 FLOWIRE ETHERNET
CONVERTER, DC VOLTAGE
• One single pair of cable can be used to
distribute power and data
• The cable hauls can be longer, reducing the
need for switches and/or repeaters
• Up to 10 Flowire devices can be connected to
the same 2-wire cluster
• Existing infrastructure can be used, even
though only a single pair is available. This
reduces the total cost of retrofit projects
• The Flowire converter can be used with
any Ethernet enabled device (not limited to
VINGTOR-STENTOFON products)
• Power 24 Vdc - 48 Vdc
Connection to Central Equipment Rack for
Outdoor and Ex Access Panels
The Exigo Access Panels can use the 2-wire Flowire system for connection.
Flowire is used to extend the Ethernet connection and support power distribution
on the 2-wire cabling infrastructure. To support the Flowire interface, the central
equipment rack must be equipped with an FCDC2 Flowire Converter. Each
outdoor access panel will require its own FCDC1 Flowire Converter.
The Ex access panel located in the hazardous zone is connected to the central
equipment rack located in the safe zone using an Ex certified 2-wire cable.
Central
Equipment Rack
Ethernet
Cable
Ethernet
Cable
FCDC2 Flowire
FCDC2 Flowire
2-wire
cable
Power
Supply 48VDC
FCDC1 Flowire
OUTDOOR
AREA
Ex Certified
2-wire cable
Ethernet
Cable
Ex Access Panel
Industrial
Access Panel
SAFE ZONE
Power
Supply 24VDC
HAZARDOUS ZONE
Size (WxHxD): 120 x 65 x 13 mm
1008080210
FCDC2 FLOWIRE ETHERNET
CONVERTER, DC VOLTAGE
Weight: 0.3 kg
• One single pair of cable can be used to
distribute power and data
• The cable hauls can be longer, up to 2 km,
reducing the need for switches and/or
repeaters
• Up to 10 Flowire devices can be connected to
the same 2-wire cluster star topology
• Existing infrastructure can be used, even
though only a single pair is available. This
reduces the total cost of retrofit projects
• The Flowire converter can be used with any
Ethernet enabled device (not limited to Vingtor-
Stentofon products)
• Protection IP-20
Important:
• 24V DC non-PoE for Ex equipment
• FCDC2 Flowire is required for Ex Call & Alarm
Panels
2990102244 / 2990102240
FLOWIRE 250 POWERBOX PSU,
48VDC/24VDC, 250W
• EN60945 compliant
• Universal input (90 – 265 Vac)
• Efficiency above 90%
• Active Power Factor Correction
• Adjustable output
• Overload and overvoltage protection
• Thermal overload protection
• Conformal coating
• DC OK signal and potential free contact
• Cooling by free air convection
• RoHS compliant
• Internal redundancy diode
• Single or parallel mode user selectable
• 2990102244: 48VDC for FCDC1
• 2990102240: 24VDC for FCDC2 with Ex panels
2990102120
FLOWIRE EX 120 POWERBOX PSU,
24VDC 120W
• EN60945 compliant
• Universal input (90 – 265 Vac)
• Efficiency above 90%
• Active Power Factor Correction
• Adjustable output
• Overload and overvoltage protection
• Thermal overload protection
• Conformal coating
• DC OK signal and potential free contact
• Cooling by free air convection
• RoHS compliant
• Internal redundancy diode
• Single or parallel mode user selectable
Size (WxHxD): 110 x 66 x 17 mm
Weight: 0.3 kg
Size (WxHxD): 132 x 50 x 128 mm
Weight 1.2 kg
Size (WxHxD): 132 x 37 x 128 mm
Weight: 0.92 kg
Theunissen Technical Trading BV | Rijksweg 191, 6581 EK Malden, Nederland
+31(0)24 358 44 55 | info@tttbv.nl | www.tttbv.nl
VINGTOR-STENTOFON EXIGO PRODUCT CATALOG 11