Offline CAN Acknowledge<br />

The Firmware parameter OfflineWithCANBusOn (is set to 1 in sample above meaning activated).<br />

CAT is able to acknowledge CAN traffic even when being Offline respectively Diagnostic Offline. This<br />

is especially then useful when CAT communicates only to one single ECU (CAN node).<br />

This behavior can be switched off to have no impact to a CAN network when CAT is Offline.<br />

Set parameter OfflineWithCANBusOn to 1 to have CAN acknowledgement even in (Diagnostic)<br />

Offline mode.<br />

Set parameter OfflineWithCANBusOn to 0 to have no CAN acknowledgement in (Diagnostic)<br />

Offline.<br />