User´s Manual - I+ME ACTIA GmbH
User´s Manual - I+ME ACTIA GmbH
User´s Manual - I+ME ACTIA GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
LED Interpretation<br />
Normal States:<br />
1) Power-On = red.<br />
Default after hardware reset.<br />
2) Firmware-Download = green.<br />
The 1st part of the firmware loader switches the LED to green.<br />
3) Normal operation OFFLINE = blinking 2 times: red, green, pause.<br />
Normally it blinks 2 times, that means all is ok.<br />
The 1st blink shows the OFFLINE state = red or the ONLINE state = green.<br />
4) Normal operation ONLINE = blinking 2 times: green, green, pause.<br />
Normally it blinks 2 times, that means all is ok.<br />
The 1st blink shows the OFFLINE state = red or the ONLINE state = green.<br />
5) Block-transfer errors while receiving commands on the RS232<br />
= blinking 4 times: red|green, green, green, green, pause.<br />
The RS232 reception module has detected problems with the RS232-block-transfer and waits for a transfer<br />
pause to reinitialize his buffers.<br />
6) Normal operation (after RS232-errors) = blinking 3 times: red|green, green, green, pause.<br />
After detecting RS232-block-transfer-errors and buffer re-initialization it is back to normal operation. It<br />
never goes back to blinking 2 times.<br />
Special States:<br />
7) Firmware-Initialization = red for 20ms, green for 20ms.<br />
The short red-green makes CAT-firmware in the first part of the initialization. It shows that the firmware<br />
now starts.<br />
8) Internal error<br />
Any other blink code indicates an internal error.<br />
In this case please note the blink code you see and send a short description about this to <strong>I+ME</strong> <strong>ACTIA</strong>.<br />
To: info@ime-actia.de<br />
<strong>I+ME</strong> <strong>ACTIA</strong> appreciates support.<br />
45