Signal List View<br />

The Signal List shown below displays up to 20 signals but only the signals that are selected to be<br />

displayed (see Signal List Configuration). Online the most recently acquired data carried by a frame<br />

will be interpreted and displayed. In Offline mode the data according to the logged data of the actual<br />

buffer entry will be displayed. (See Buffer Handling )<br />

The color of the characters for the signal value changes from black to red and vice versa each time the<br />

same signal is received again.<br />

Time:<br />

The accumulated time after going online is updated each time when the frame is received. Online the<br />

time is shown in ms,ms/10. Offline the time is shown as hour:min:sec,ms.<br />

Delta:<br />

Only available offline the delta time is shown in ms,ms/10 between the actual receiving of the frame<br />

and the last receiving of the same frame (with the same ID).<br />

Name:<br />

Displays the defined name of the signal.<br />

Value:<br />

Displays the interpreted value in accordance to the Data carried by the received frame.<br />

Unit:<br />

Displays the defined Unit of the signal.<br />

See also how to define a Signal and how to configure the Signal List for more details.)<br />