Terms & Phrases<br />
Block Size (BS) The BS (Block Size) defines the maximum number of frames which can be send before another<br />
flow control frame has to be sent.<br />
Buffer Used as synonym for the data of the circular buffer on the Hardware. See also Buffer Handling .<br />
Configurations All the setups that are done to change or modify a session not the database. Though there is an<br />
access to maintain the databases via the menu item Configurations.<br />
CPID Control Packet Identifier. 1 Byte value identifies a packet of data bytes to control and manipulate<br />
ECUs (Devices) externally.<br />
Database The term database is here used to determine the data that describe vehicles by the build in<br />
ECUs, the frames of each ECU and the signals of each frame.<br />
Parts of a Database are:<br />
16<br />
- included vehicles,<br />
- included ECUs,<br />
- included Frames and Diagnostic data,<br />
- included Signals.<br />
Each vehicle contains ECUs; the ECUs contain Frames and Diagnostic data. Frames and<br />
Diagnostic data each contain Signals.<br />
DID Data Identifier. 1 Byte value identifies static information stored in the ECUs.<br />
DPID Data Packet Identifier. 1 Byte value identifies a packet of diagnostic data bytes containing nonstatic<br />
information.<br />
DTC Diagnostic Trouble Code.<br />
ECU Electronic Control Unit. Here in the meaning of electronic boxes that are build in vehicles and that<br />
communicate via the CAN bus.<br />
Filter CAT provides Pass Through Filter only. The data are already filtered by the Hardware.<br />
Frame The frames are the messages that are transported via the CAN bus.<br />
FSA Functional System Address. Identifies a group of ECUs that build up a functional system.<br />
Layout The layout means the desktop and desktop configuration of CAT application.<br />
Padding Padding means to fill up the Data Byte Field of CAN Frames with 0's, so that the frames always<br />
contain 8 Data Bytes.<br />
Separation Time The ST (Separation Time) defines the minimum amount of time in ms, which must be between<br />
consecutive frame transmissions of a multi frame message.<br />
Session The term session is here used to describe the settings done to work with CAT<br />
Parts of a Session are:<br />
- the link to a database,<br />
- the frames that shall be displayed in the frame list window,<br />
- the signals that shall be displayed in the signal list window,<br />
- the configured frames that shall be transmitted inclusive the conditions,<br />
- the filter conditions,<br />
- the CAN setups (selected or configured physical layer / Baud Rate),<br />
- the buffer division sizes,<br />
- the buffer content (when uploaded)<br />
- the layout settings for the graphical user interface, column / fonts sizes and windows<br />
arrangements.<br />
Signal The signals are the interpreted data of the CAN frame. See also chapter Signal Types.<br />
Trigger Trigger used as short form for trigger event. There is a trigger event when the trigger conditions<br />
are fulfilled. Trigger events are not necessarily frames that appear on the bus. See also chapter Configurations |<br />
Trigger.