ECC:<br />

CAT reads out The Error Code Capture (ECC) register of the SJA1000 CAN controller. The<br />

hexadecimal value (here D9) is displayed and interpreted. The meaning is displayed as real text.<br />

The first text part (here Tx) is the interpretation of the ECC.5 Bit, indicating if the error occurred during<br />

reception or transmission.<br />

The second text part (here Other) is the interpretation of the ECC.6 Bit & ECC.7 Bit, indicating the<br />

error type. Possible types are Bit, Form, Stuff and Other Errors. Other stands for CRC or<br />

Acknowledgement Errors.<br />

The third text part (here Acknowledge Slot) is the interpretation of the ECC.0 Bit to ECC.4 Bit,<br />

indicating the error event.<br />