Error Interpretation<br />

The status bar of CAT provides in any mode but the Diagnostic Online mode information about the<br />

CAN bus status:<br />

Bus Status:<br />

The Bus Status as provided by the status flag of the CAN chip is displayed.<br />

Rx Errors:<br />

Different to the bus status not the Rx counter as provided by CAN chip is displayed but the real number<br />

of Rx Errors that have occurred on the bus since going online are displayed. Independent of the Error<br />

Type the counter is increased each time by one.<br />

Tx Errors:<br />

Different to the bus status not the Tx counter as provided by the CAN chip is displayed but the real<br />

number of Tx Errors that have occurred on the bus since going online are displayed. Independent of the<br />

Error Type the counter is increased each time by one.<br />

In Offline Mode the Trace List View as shown below provides additionally an interpretation of the<br />

Error Code Capture register of the SJA1000 CAN controller used by CAT.<br />

Accu:<br />

The accumulated numbers of Rx and Tx errors occurred on the bus are displayed. (The same value that<br />

is provided by the status bar.)<br />

Chip:<br />

The Rx and Tx error counter values are displayed, as provided by the CAN chip.<br />

Note: The error counters are modified according to certain rules. So the step size of increasing a<br />

counter allows already an interpretation. Generally the counter increases by 8 if the node probably is<br />

responsible for the error itself. Otherwise it is increased by 1.<br />