Device Control Reset<br />

The purpose of the service Device Control ($AE) is to allow CAT to override normal output control<br />

functions in order to verify proper operation of a component or system, or to reset/clear variables used<br />

within normal control algorithms. See Device Control for details about this service.<br />

In generally Device Control Reset is absolutely identical to the service Device Control. Even the same<br />

CPID table as shown below has to be used. But the fact that CAT provides this service twice allows the<br />

user to set up these both in different ways. Meaning the user selects a different CPID (of the max. 10<br />

available) for the Device Control Reset service than for the Device Control service.<br />

This allows the user to launch two different Device Control services without going offline to change the<br />

settings. Especially to Reset the service this feature is needed.<br />

Note: This service should only be requested using physical addressing. See the Main Diagnostic<br />

Setup window for details about addressing.<br />