Read Failure Record Parameters<br />

The service Read Failure Record Data ($12) is used to obtain failure record information that was<br />

captured due to a fault detected within the node.<br />

CAT provides two already predefined setup levels of the Read Failure Record Data service:<br />

- The Read Failure Record Identifiers (sub-function parameter = $01),<br />

- The Read Failure Record Parameters (sub-function parameter = $02).<br />

Read Failure Record Parameters (sub-function parameter = $02) allows CAT to retrieve the data<br />

parameters in the failure record associated with the failure record identifier. Failure record data<br />

parameters consist of ECU inputs, outputs, and calculated values, which provide information about the<br />

operating conditions of the vehicle at the time the DTC, is logged.<br />

To read out the parameters of the failure record the Failure Record Identifier has to be configured. The<br />

Setup button in the Main Diagnostic Setup window could activate the dialog box shown below.<br />

The Failure Record Identifier consists of 4 bytes, which include the Failure Record Number and the<br />

DTC Identifier (2 byte DTC number + 1 byte DTC fault type).<br />

Note: Valid failure record identifier data values are obtained by CAT from the Read Failure Record<br />

Identifiers ($01) level of this service.<br />

Input the desired Identifier and acknowledge the setup by OK.<br />

134