Read Failure Record Identifier<br />

The service Read Failure Record Data ($12) is used to obtain failure record information that was<br />

captured due to a fault detected within the node.<br />

CAT provides two already predefined setup levels of the Read Failure Record Data service:<br />

- The Read Failure Record Identifiers (sub-function parameter = $01),<br />

- The Read Failure Record Parameters (sub-function parameter = $02).<br />

Read Failure Record Identifiers (sub-function parameter = $01) allows CAT to obtain the information<br />

necessary to send a request to retrieve the data parameters associated with a specific failure record<br />

stored in a node.<br />

Note: This level is only used to obtain the failureRecordDataStructureIdentifier parameter and the<br />

failure record identifiers. The data bytes contained within a particular failure record are retrieved with<br />

the Read Failure Record Parameters ($02) level.<br />

There are no additional setups needed / allowed for the Read Failure Record Identifiers level.<br />