Trigger<br />
CAT allows defining a Trigger Event based on Frame Identifier and Data. This Trigger is used to set a flag into the<br />
logged buffer and to stop the logging of data. Therefore the user can define by Pre/ Post Trigger how many frames<br />
shall be stored before and after the trigger event occurs.<br />
The feature Time Out Trigger allows to trigger on the lacking of a frame. To use a frame from the database there is an<br />
easy access button to the frame list. (See Trigger on existing Frames)<br />
Choose menu item Configurations | Trigger from the main window to open the Trigger<br />
Configuration... window shown above.<br />
Enable Trigger: Click into this box and get it marked to enable triggering on the defined conditions. Otherwise the<br />
occurrence of a defined frame will have no influence to the logging process at all.<br />
Note: Enable trigger has to be marked to enable the input or edit from all other<br />
input fields in this dialog.<br />
The trigger sign in the status bar becomes yellow when Trigger is enabled.<br />
Use Frame List : Click this button to access the Frame List allowing choosing one or more predefined Frame. Then<br />
the frame ID, format, number of data bytes and the default data will be implemented automatically in order to create a<br />
trigger condition.<br />
Format: Choose standard (STD 11bit Identifier) or extended (XTD 29bit Identifier) format.<br />
Number<br />
of Data Bytes: Choose the number of data bytes that the trigger condition to be triggered on must have.<br />
Tip: Input "0" to trigger only on the Identifier. The Data Bytes will not be<br />
considered as trigger condition.<br />
Note: If a frame contains more data bytes then required it still is a trigger condition<br />
as long as the data bytes, which are required, fulfil the Data Byte Trigger conditions<br />
described below.<br />