The first data byte (Byte 0) of the response message frame is used and reserved for the DPID. So there<br />

are only 7 data bytes left for the signals: Byte 1 to 7. Therefore the selectable starting bytes are Byte 1<br />

to 7 and depending on Signal Type and Format the maximal length is 7 Bytes, 56 Bits respectively.<br />

For more detailed Information about handling the different signal types and formats see also chapter<br />

Signal Types:<br />

108<br />

Boolean Signals,<br />

Engineering Signals,<br />

Packed Binary Coded Decimal Signals,<br />

Signed Integer Signals,<br />

State Encoded Value Signals,<br />

String Signals,<br />

Unsigned Integer Signals<br />

Note: In the screenshots used to describe the different signal types, the signals are always assigned to<br />

a frame and not to a DPID. So you see as assignment Frame: instead of DPID: .