Weidmueller Heavy Duty Connectors
Fibre optic contacts RockStar ® accessories Fibre optic contacts Fibre-optic cables guarantee interference-free transmission without any feedback. The new fibre-optic contacts can now also be used in heavy-duty connectors. Their shape corresponds to that of our proven HD contacts for connecting conventional copper wires. Accordingly, they can be assembled in existing connectors of the HD series, as well as being suitable for use with the ConCept modular system. It is even possible to connect fibre-optic wires and copper wires in a single connector. The advantages at a glance: • Immune to electromagnetic interference • Absolute contact separation • Weight reduction by dispensing with copper wires • High transmission capacity and large bandwidth • All advantages now also available for robust industrial environments I HDC-C-HD ... LWL 1.0 POF Technical data Connection for POF cable Maximum outer diameter Polymer fibre diameter 2.2 mm 1.0 mm Attenuation – Requirement to DIN IEC Part 7 Section 2/05.94: < 3 dB – the HDC-C-HD LWL contacts in plugged-in state: < 2 dB Material Temperature range –40 °C to +85 °C Contact material Nickel-silver Over-spring Copper alloy Ordering data Qty. Male Order No. Female Order No. 5 HDC-C-HD-S-LWL 1.0 POF 1773630000 HDC-C-HD-B-LWL 1.0 POF 1773640000 HD inserts must be ordered separately I.8 2028800000
Fibre optic contacts Instructions for assembling fibre optic contacts 1. Cut POF cable (polymer optical fibre) to the required length with cutting tool (we recommend the KT 8). 2. The end face of the fibre of 2.2 mm POF cables must be polished before crimping onto the fibre optic contact. Insert end of POF cable into polishing disc and polish with polishing sheet placed on a smooth surface (e.g. glass plate). Wipe away any residues after polishing. The best optical attenuation values are obtained with wet polishing. 3. Strip sheath of 2.2 mm POF cable to at least 14 mm for female contacts (HDC-C-HD-B-LWL) and at least 19 mm for male contacts (HDC-C-HD-S-LWL). 4. Crimping: A. Insert POF cable into male contact, then both together into the crimping die. B. The female contact has to be inserted angled slightly downwards into the die. Make sure the end face of the contact and the plastic fibre press against the locator. C. Squeeze the hand levers until the tool unlocks. D. Release option in case of incorrect operation. Cutting tool including positioning sleeve Type Qty. Order No. Polishing disc for fibre-optic cable Polishing sheet, 1,000 grit size 2.2 mm POF cable KT8 1 1096180000 Type Qty. Order No. PS LWL/POF 1 9020390000 PB LWL/POF 1 9020400000 Stripping tool for fibre-optic cable Type Qty. Order No. AM LWL/POF 1 9020360000 RockStar ® accessories A. Male B. Female I Crimping tool for fibre-optic set Type Qty. Order No. HTX-HDC/POF 1 9010950000 C. D. Contact release tool for removing machined HD and fibre-optic contacts Type Qty. Order No. Removal Tool HD 1 1866730000 2028800000 I.9
- Page 253 and 254: Introduction Practical Laser labell
- Page 255 and 256: 6 RockStar ® Housings IP68 / EMC S
- Page 257 and 258: 6 RockStar ® Housings IP68 / EMC S
- Page 259 and 260: RockStar ® Housings IP68 / EMC Scr
- Page 261 and 262: Contents RockStar ® Data Connector
- Page 263 and 264: b IE-LINE Variant 5 RockStar ® hea
- Page 265 and 266: IE-LINE Variant 5 RJ45 plug inserts
- Page 267 and 268: IE-LINE Variant 5 RJ45 flange inser
- Page 269 and 270: Contents RockStar ® Kits RockStar
- Page 271 and 272: Introduction RockStar ® Kits Easy
- Page 273 and 274: Kits with HA inserts, 3 pole 400 V,
- Page 275 and 276: Kits with HA inserts, 4 pole 400 V,
- Page 277 and 278: Kits with HE inserts, 6 pole 500 V,
- Page 279 and 280: Kits with HE inserts, 6-pole, PUSH
- Page 281 and 282: Kits with HE inserts, 10 pole 500 V
- Page 283 and 284: Kits with HE inserts, 10-pole, PUSH
- Page 285 and 286: Kits with HE inserts, 16 pole 500 V
- Page 287 and 288: Kits with HE inserts, 16-pole, PUSH
- Page 289 and 290: Kits with HE inserts, 24 pole 500 V
- Page 291 and 292: Kits with HE inserts, 24-pole, PUSH
- Page 293 and 294: Kits with HE inserts, 32 pole 500 V
- Page 295 and 296: Kits with HE inserts, 48 pole 500 V
- Page 297 and 298: Contents RockStar ® accessories Ro
- Page 299 and 300: Introduction Secure Solid, machined
- Page 301 and 302: Crimp contacts Crimp contacts for f
- Page 303: Crimp contacts Technical data Mater
- Page 307 and 308: Coding Coding system with guiding f
- Page 309 and 310: Coding HE coding pin Use the HE cod
- Page 311 and 312: Shield lever Shield lever for stand
- Page 313 and 314: Shield lever RockStar ® accessorie
- Page 315 and 316: Other accessories HDC GRIP PANEL Te
- Page 317 and 318: D E F Other accessories HDC screw a
- Page 319 and 320: Other accessories Profile seals Gas
- Page 321 and 322: Content Tools Tools Tools Cutting J
- Page 323 and 324: Crimping Crimping tools for other c
- Page 325 and 326: Crimping MTR 160 Cross-section Code
- Page 327 and 328: Crimping Crimping tools for HighPow
- Page 329 and 330: Crimping HTX-HDC/POF POF crimping C
- Page 331 and 332: Screwdrivers VDE-insulated torque s
- Page 333 and 334: Screwdrivers Uninsulated screwdrive
- Page 335 and 336: Screwdrivers Weidmüller wrench set
- Page 337 and 338: Miscellaneous Removal Tool CM3, HD
- Page 339 and 340: Inhalt Cable entries Cable entries
- Page 341 and 342: Introduction You should always obse
- Page 343 and 344: Standard cable glands - Plastic Cab
- Page 345 and 346: Standard cable glands - Brass Cable
- Page 347 and 348: Standard cable glands - Brass Cable
- Page 349 and 350: EMC cable glands Cable glands - Bra
- Page 351 and 352: EMC cable glands Cable glands - bra
- Page 353 and 354: Standard cable glands - Stainless s
Fibre optic contacts<br />
RockStar ® accessories<br />
Fibre optic contacts<br />
Fibre-optic cables guarantee interference-free transmission<br />
without any feedback.<br />
The new fibre-optic contacts can now also be used in<br />
heavy-duty connectors. Their shape corresponds to that of<br />
our proven HD contacts for connecting conventional copper<br />
wires. Accordingly, they can be assembled in existing<br />
connectors of the HD series, as well as being suitable for<br />
use with the ConCept modular system. It is even possible<br />
to connect fibre-optic wires and copper wires in a single<br />
connector.<br />
The advantages at a glance:<br />
• Immune to electromagnetic interference<br />
• Absolute contact separation<br />
• Weight reduction by dispensing with copper wires<br />
• High transmission capacity and large bandwidth<br />
• All advantages now also available for robust industrial<br />
environments<br />
I<br />
HDC-C-HD ... LWL 1.0 POF<br />
Technical data<br />
Connection for POF cable<br />
Maximum outer diameter<br />
Polymer fibre diameter<br />
2.2 mm<br />
1.0 mm<br />
Attenuation<br />
– Requirement to DIN IEC Part 7 Section 2/05.94: < 3 dB<br />
– the HDC-C-HD LWL contacts in plugged-in state: < 2 dB<br />
Material<br />
Temperature range –40 °C to +85 °C<br />
Contact material<br />
Nickel-silver<br />
Over-spring<br />
Copper alloy<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Ordering data<br />
Qty. Male Order No. Female Order No.<br />
5 HDC-C-HD-S-LWL 1.0 POF 1773630000 HDC-C-HD-B-LWL 1.0 POF 1773640000<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
HD inserts must be ordered separately<br />
<br />
<br />
I.8 2028800000