06.11.2019 Views

Weidmueller Heavy Duty Connectors

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical data<br />

Using wire-end ferrules<br />

Overview<br />

A<br />

Type of connection Series HA HE HVE HSB<br />

Screw Clamping range [mm 2 ] 0.5 – 2.5 0.5 – 2.5 0.5 – 2.5 –<br />

Clamping range [AWG] 20 – 12 20 – 14 (12) 1) 20 – 14 (12) 1) –<br />

Ferrules with collars H0.5/14 – H2.5/14 H0.5/14 – H2.5/14 2) H0.5/14 – H2.5/14 2) –<br />

H0.5/16 – H2.5/16 H0.5/16 – H2.5/16 2) H0.5/16 – H2.5/16 2)<br />

Ferrules without collars H0.5/10 – H2.5/10 H0.5/10 – H2.5/10 H0.5/10 – H2.5/10 –<br />

Twin wire-end ferrules<br />

with collars<br />

H0.5/16.5 (ZH) H0.5/18.5 (ZH) – H0.5/15 (ZH)<br />

H0.5/18.5 (ZH) H1.0/20 (ZH) 3) H0.5/16.5 (ZH)<br />

H0.75/17 (ZH) H1.5/20 (ZH) 3) H0.5/18.5 (ZH)<br />

H1.0/20 (ZH)<br />

H0.75/15 (ZH)<br />

H1.5/20 (ZH)<br />

H0.75/17 (ZH)<br />

H1.0/15 (ZH)<br />

H1.0/20 (ZH)<br />

H1.5/16 (ZH)<br />

H1.5/20 (ZH)<br />

H2.5/18.5 (ZH)<br />

Crimp tool PZ4 2) , PZ6, PZ6/5 PZ4 2) , PZ6, PZ6/5 PZ4 2) , PZ6, PZ6/5 –<br />

PZ6 Hex 2) PZ6 Hex 2)<br />

Screwdriver SDK PH0 SDK PH0 SDK PH0 –<br />

SD 0.5x 3.0 SD 0.5x 3.0 SD 0.5x 3.0<br />

Tightening torque 0.5 Nm 0.5 Nm 0.5 Nm –<br />

Tension clamp Clamping range [mm 2 ] 0.25 – 1.5 0.25 – 2.5 0.25 – 2.5 –<br />

2.5 solid core<br />

Clamping range [AWG] 24 – 14 4) 24 – 14 24 – 14 –<br />

Ferrules with collars H0.5/14 – H1.5/14 4) H0.5/14 – H2.5/14 2) H0.5/14 – H2.5/14 2) –<br />

H0.5/16 – H1.5/16 4)<br />

Ferrules without collars H0.5/10 – H1.5/10 4) – – –<br />

Twin wire-end ferrules<br />

with collars<br />

– H0.5/15 (ZH) 5) or 6) – –<br />

H0.75/15 (ZH) 5) or 6)<br />

H1.0/15 (ZH) 5) or 6)<br />

H1.5/16 (ZH) 5) or 6)<br />

Crimp tool PZ4, PZ6, PZ6/5 PZ4 7) , PZ6, PZ6/5 PZ4 7) , PZ6, PZ6/5 –<br />

Screwdriver SD 0.5x 3.0 SD 0.6x 3.5 SD 0.6x 3.5 –<br />

PUSH IN Clamping range [mm 2 ] – solid 0.5 – 4 mm 2 – –<br />

flexible with ferrule<br />

0.5 – 2.5 mm 2<br />

Clamping range [mm 2 ] – 20 – 12 – –<br />

Ferrules with collars – H0.5/14 – H1.5/14 – –<br />

– H0.5/16 – H1.5/16 – –<br />

– H0.75/18 – H2.5/18 2) – –<br />

Ferrules without collars – H0.5/10 – H2.5/10 2) – –<br />

– H1.5/12 – H2.5/12 2) – –<br />

Twin wire-end ferrules<br />

with collars<br />

– H0.5/18.4 ZH 500 V / 6 kV / 3 – –<br />

H1/20 ZH 400 V / 6 kV / 3<br />

500 V / 6 kV / 3 only with protection degree of at least IP54<br />

H1.5/20 ZH 400 V / 6 kV / 3<br />

500 V / 6 kV / 3 only with protection degree of at least IP54<br />

Ferrules crimped with – PZ4. PZ6. PZ6/5. – –<br />

PZ6 Hex<br />

PE contact Clamping range [mm 2 ] 0.5 – 4.0 0.5 – 4 0.5 – 4 –<br />

0.5 – 2.5 flexible<br />

Clamping range [AWG] 20 – 12 20 – 12 20 – 12 –<br />

Ferrules with collars H0.5/16 – H2.5/16 H0.5/16 – H4/16 H0.5/16 – H4/16 –<br />

Ferrules without collars H0.5/10 – H2.5/10 H0.5/10 – H4/10 H0.5/10 – H4/10 –<br />

Ferrules crimped with PZ4 2) , PZ6, PZ6/5 PZ4, PZ6, PZ6/5, PZ4, PZ6, PZ6/5, –<br />

PZ6 Hex<br />

PZ6 Hex<br />

Screwdriver PH 1 PH 1 PH 1 –<br />

Tightening torque 1.2 Nm 1.2 Nm 1.2 Nm –<br />

1)<br />

Depending on the diameter of the insulation, the max. AWG wire may need to be pushed in with some force.<br />

2)<br />

The 2.5mm 2 wire must be inserted with some force.<br />

3)<br />

When the rated voltage is reduced to 400 V / 6 kV / 3 or with a protection degree of at least IP54.<br />

4)<br />

Only by tilting the screwdriver can the clamping point be opened all the way.<br />

5)<br />

Wire-end ferrules may be used when the rated voltage is reduced to 400 V / 6 kV / 3.<br />

6)<br />

When the protection degree is at least IP54, the creepage and clearance distances within the encapsulation may<br />

be rated for a lower pollution degree (DIN EN 61984). For this encapsulation, the use of wire-end ferrules is<br />

possible with 500 V / 6 kV / 3.<br />

7)<br />

The PZ4 crimping tool should not be used with the max. wire size.<br />

The connector inserts can be combined with wire-end ferrules in other ways depending on the available clamping range and the type of cable being used.<br />

We would be happy to take a look at the technical feasibility of your specific application.<br />

A.16 2028800000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!