06.11.2019 Views

Weidmueller Enclosures & Cable Glands

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Directive 1999/92/EC<br />

Technical appendix<br />

The system of EPL classifications (Equipment Protection<br />

Level) is shown below.<br />

Firedamp (methane) risk mines (Group I)<br />

EPL Ma<br />

Equipment for installation in mining applications, offering a<br />

„very high“ level of protection and which do not constitute a<br />

source of ignition during normal operation, or in the event of<br />

rarely occurring faults.<br />

EPL Mb<br />

Equipment for installation in a mine with a high level of<br />

rotection. Has sufficient safety to ensure that there is no<br />

source of ignition in the period of time between the outbreak<br />

of gas and the time the equipment is switched off.<br />

Gases (Group II)<br />

EPL Ga<br />

Equipment for explosive-risk gas atmospheres with a very<br />

high level of protection. No source of ignition is present<br />

during normal operation or when errors occur that cannot be<br />

necessarily expected on a regular basis.<br />

Dust (Group III)<br />

EPL Da<br />

Equipment for combustible dust atmospheres with a very<br />

high level of protection. No source of ignition is present<br />

during normal operation or in very rare faults.<br />

EPL Db<br />

Equipment for combustible dust atmospheres with a high<br />

level of protection. No source of ignition is present during<br />

normal operation or when errors occur that cannot be<br />

necessarily expected on a regular basis.<br />

EPL Dc<br />

Equipment for combustible dust atmospheres with an<br />

elevated level of protection. No source of ignition is<br />

present during normal operation and it can have additional<br />

safeguards to ensure that none is present during faults<br />

which happen regularly (e. g. failure of a lamp).<br />

EPL Gb<br />

Equipment for explosive-risk gas atmospheres with a high<br />

level of protection. No source of ignition is present during<br />

normal operation or when errors occur that cannot be<br />

necessarily expected on a regular basis.<br />

EPL Gc<br />

Equipment for explosive-risk gas atmospheres with an<br />

elevated level of protection. No source of ignition is<br />

present during normal operation and it can have additional<br />

safeguards to ensure that none is present during faults<br />

which happen regularly (e. g. failure of a lamp).<br />

W<br />

W.4<br />

2031180000