Klippon ® <strong>Cable</strong> <strong>Glands</strong><br />

<strong>Cable</strong> entries<br />

2. Selection of the material [b], the sealing material [c] and the plating [e] of the cable gland<br />

Order key [Type] [a] [b] [c] [d] [e] [f] [ggg]<br />

Example Article Description KDSU O<br />

D<br />

2a) Selection of the material [b]<br />

All cable gland types are made from brass “b”. Other materials can also be provided upon request.<br />

Consequently is<br />

[b] = B<br />

2b) Selection of the sealing material [c] based on the required temperature range<br />

The cable glands can be ordered with either a neoprene seal “N” or a silicone seal “S”.<br />

<strong>Glands</strong> with a neoprene seal can be used in a temperature range from -20 °C to +85 °C, whereas glands with silicone seal maintain a temperature range<br />

from -60 °C to +180 °C. (KUB glands are certified to a temperature of -60 °C to +85 °C).<br />

[Type] [c] Seal material<br />

KDSU N,S Neoprene, Silicone<br />

KDSW N,S Neoprene (with continuity for lead sheath), Silicone<br />

KDSX S Silicone<br />

KSG N,S Neoprene, Silicone<br />

KUB N Silicone (-60 °C to +85 °C)<br />

Because the enclosure in the example case operates in a temperature range of -25 °C to +45 °C, a cable gland with a silicone seal has to be used.<br />

Consequently is<br />

[c] = „S“ (Silicone)<br />

2c) Selection of the plating [e]<br />

All cable glands can be provided either with nickel plated surface “NI” or with self-coloured surface “SC”.<br />

In the example case the enclosure is used outdoor, therefore it can come into contact with water in form of rain, so that a cable gland<br />

with nickel plated surface as protection against corrosion and wear has to be selected. Consequently is [e] = „NI“<br />

The generated information has to be filled into the order key below:<br />

Order key [Type] [a] [b] [c] [d] [e] [f] [ggg]<br />

Example Article Description KDSU B S O NI<br />

3. Selection of the entry thread [a], the cable outer sheath variant [f] and the gland size [ggg]<br />

Order key [Type] [a] [b] [c] [d] [e] [f] [ggg]<br />

Example Article Description KDSU B S O NI<br />

The suitable gland size [ggg] will be selected based on the inner and outer sheath diameters of the cable. Thereby the entry thread size [a] and<br />

the cable outer sheath variant [f] result.<br />

D.28 2031180000