feature sheet<br />
included by vendor<br />
Ceiling height on each floor<br />
12’ to underside of slab or deck<br />
ground level entry doors<br />
8’ height 36” wide Aluminium framed glass doors<br />
floor and ceiling<br />
Core slab, poured or open web steel joist with concrete topping<br />
ground floor plumbing<br />
4” sanitary service roughed into unit. It shall be located in the floor at Vender’s<br />
discretion. Includes a 3” plumbing vent installed through the roof for future plumbing by<br />
the Purchaser. All above floor plumbing, water, fixtures and finishes shall be completed<br />
by the Purchaser<br />
Second floor plumbing<br />
Rough-in drain for 2 piece washroom located in floor at Vendor’s discretion; all above<br />
floor plumbing, water, fixtures and finishes shall be completed by the Purchaser<br />
water<br />
The Vendor will provide 1” water line for domestic water service stubbed into<br />
the unit with shut-off valve<br />
Hvac<br />
HVAC Each unit will have 1 individually controlled Natural Gas combination<br />
Heating/cooling roof top unit with gas piping and electrically connected. Each HVAC<br />
unit shall have sheet metal supply & return air duct stubs into unit and terminate at<br />
the bottom of the structural steel joist, for future duct distribution by the Purchaser. A<br />
thermostat with 50’ of coiled control wiring shall be left in the unit. The final installation<br />
of the thermostat is the Purchasers responsibility<br />
1,800 sq. ft. units to receive a 3 ton unit<br />
2,400 sq. ft. units to receive a 5 ton unit<br />
Each unit shall be provided with (2) 6” capped exhaust vents to exterior (through roof<br />
or wall) for future venting requirements<br />
Hydro<br />
The Vendor will provide 100 AMP, 600 volt electrical service complete with a rough<br />
roof or wall) for future venting requirements disconnect switch, splitter and feed to the<br />
heating/cooling unit<br />
communications<br />
The Vendor shall provide 1 conduit from unit to a common area demarcation point<br />
**Only the items listed shall be provided and installed by the vendor in accordance with the Agreement of Purchase & Sale. The Vendor is not required to provide any material; or to do any work to or in respect of the purchased unit , except the work and<br />
materials listed in the Schedule “D” of the Agreement of Purchase & Sale. The Vendor’s work will be performed in accordance with the Vendor’s choice of materials.<br />