15. Shell and Tube Mean Metal Temperatures are the average metal<br />

temperatures through the shell and tube thicknesses integrated over the<br />

length of the heat exchanger for a given steady state operating condition.<br />

16. Shut-Down Conditions are the conditions of operation which exist from<br />

the time of steady state operating conditions to the time that flow of both<br />

process streams has ceased.<br />

17. Start-Up Conditions are the conditions of operation which exist from the<br />

time that flow of either or both process streams is initiated to the time that<br />

steady state operating conditions are achieved.<br />

18. Support plate is a device to support the bundle or to reduce unsupported<br />

tube span without consideration for heat transfer.<br />

19. Tubesheet Ligament is the shortest distance between edge of adjacent<br />

tube holes in the tube pattern.<br />

20. Welded Tube Joint is a tube-to-tubesheet joint where the tube is welded<br />

to the tubesheet.<br />