BiLO®-UBt-connector - BiERBACH GmbH & Co. KG ...
BiLO®-UBt-connector - BiERBACH GmbH & Co. KG ...
BiLO®-UBt-connector - BiERBACH GmbH & Co. KG ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
The perfect connection<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong><br />
”One for all“ – invisible<br />
EFFICIENT TIMBER JOINTS!<br />
Use:<br />
Staircase construction<br />
<strong>Co</strong>nservatory construction<br />
Remodelling<br />
Drywall<br />
Gardening and landscaping<br />
Exhibition stand construction<br />
Store construction<br />
<strong>Co</strong>vered balcony construction<br />
Carport construction<br />
Advertising signs<br />
®<br />
BiLO<br />
Z-9.1-651<br />
NRW 02
The perfect connection<br />
General building inspections permit Z-9.1-651 • General building inspections permit Z-9.1-651 • G<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> ”One for all“<br />
Orthogonal connection of support-bolt. Horizontally installed <strong>connector</strong>.<br />
Orthogonal and horizontally sloped connection of<br />
the main beam - secondary beam.<br />
Vertically upward slanted<br />
connection/support-bolt.<br />
Pre-assembled main/secondary beam.<br />
<strong>Co</strong>nnection: Sinking at the main beam.<br />
00.2<br />
Secondary beam or purlin<br />
connection to OSB outdoors.<br />
Vertically downward slanted<br />
connection/support-bolt.<br />
Orthogonal connection of the<br />
main/secondary beam.<br />
EFFICIENT TIMBER JOINTS:<br />
No slitting and tapping - the BiLO ® -<strong>UBt</strong>-<strong>connector</strong> connects timber joints<br />
of solid wood and wood material quickly and invisibly.<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong>s are manufactured of 4 mm thick steel and are<br />
galvanized all-around.<br />
The BiLO ® -<strong>UBt</strong>-<strong>connector</strong> is marked by numerous application options<br />
at a high flexibility in planning and the design of wood structures.<br />
The wide-range selection of the <strong>connector</strong> sizes allows the optimal<br />
implementation of all connections in static wood construction.<br />
The invisible use of the <strong>connector</strong>s enables clean component connecting<br />
joints, which meet the highest aesthetic demands.<br />
The BiLO ® -<strong>UBt</strong>-<strong>connector</strong> can support loads in hanging direction<br />
(symmetric axis) lateral to the hanging direction as well as tensile forces.<br />
Forces against the slide-in direction (such as lifting forces) can be absorbed<br />
in conjunction with the BiRA ® -HK-screw <strong>connector</strong>. The simple, filed<br />
plug-in system of the BiLO ® -<strong>UBt</strong>-<strong>connector</strong>s provides the employee with<br />
great potential cost-reductions.<br />
Potential applications of the<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong>:<br />
MAIN-SECONDARY BEAM JOINTS<br />
visible or invisible<br />
• Horizontal joints below 90° (orthogonal connections).<br />
• Horizontal slanted connections.<br />
• Vertically slanted connections.<br />
• Sloped connections, such as purlins on <strong>connector</strong>s in the roof slope.<br />
• <strong>Co</strong>nnections to the OSB sheets outdoors.<br />
POST, SCREW CONNECTIONS<br />
visible or invisible<br />
• Horizontal joints below 90° (orthogonal connections).<br />
• Horizontal slanted connections.<br />
• Vertically slanted connections.<br />
Vertical downward sloped connection<br />
of the main/secondary beam.<br />
®<br />
BiLO<br />
Z-9.1-651<br />
NRW 02<br />
Vertical upward sloped connection<br />
of the main/secondary beam.
eneral building inspections permit Z-9.1-651 • General building<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> ”One for all“<br />
ADDITONAL APPLICATION OPTIONS<br />
of visible or invisible connections<br />
• For connecting tanner purlins.<br />
• For connecting wall elements in wood frame construction.<br />
• For connecting beam structures.<br />
• For connecting ridge connections.<br />
• For attaching pre-manufactured attaching elements in interior finishing.<br />
• For attaching platforms with covered balconies.<br />
• For attaching balcony railings (posts and handrails).<br />
• Versatile connections for the construction of conservatories, summer<br />
houses, saunas, arbours, exhibition stands, carports.<br />
Installation with shadow gap<br />
ASSEMBLY INFORMATION<br />
• The BiLO ® -<strong>UBt</strong>-<strong>connector</strong> is marked on the main beam, support or purlin is marked (according to the<br />
installation position of the secondary beam) and bolted together with BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws<br />
under 90°. The centre web (finger) points upward against the attachment direction.<br />
• The installation position of the BiLO ® -<strong>UBt</strong>-connection is measured and marked on the secondary beam.<br />
• Position the <strong>connector</strong> and screw together with BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws below 90°.<br />
• The centre web (finger) points down in the attachment direction.<br />
• Advantage of the 90° bolting compared to the slanted bolting:<br />
The positioned <strong>connector</strong> does not shift.<br />
• It is attached with diameter 6 x 80 mm BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws.<br />
Installation without a shadow gap<br />
(e.g. main-secondary beam)<br />
ASSEMBLY INFORMATION<br />
• BiLO ® -<strong>UBt</strong>-<strong>connector</strong> is marked on the main beam according<br />
to the installation position of the secondary beam and<br />
lowered 8.5 - 9 mm deep.<br />
• Place the BiLO ® -<strong>UBt</strong>-<strong>connector</strong> in the milled-out portion and<br />
bolt with BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws, diameter 6 x 80 mm under 90°.<br />
• The centre web (finger) points upward against the attachment direction.<br />
• The installation position of the BiLO ® -<strong>UBt</strong>-connection is measured<br />
and marked on the secondary beam.<br />
• Position the <strong>connector</strong> and screw together with<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws below 90°.<br />
®<br />
BiLO<br />
Z-9.1-651<br />
NRW 02<br />
EFFICIENT TIMBER JOINTS!<br />
Main/secondary beam connection,<br />
main beam is sloped vertically.<br />
Orthogonal connection:<br />
Support crossbar.<br />
<strong>Co</strong>nnecting a tanner‘s purlin with a shadow gap.<br />
Pre-assembled HT – NT connection.<br />
Sinking at the main beam.<br />
<strong>Co</strong>nnection sloping vertically<br />
downward: Support crossbar.<br />
Sinking,<br />
bolting,<br />
attaching,<br />
finished<br />
Ridge connection installed laterally<br />
with shadow gap <strong>connector</strong>.<br />
<strong>Co</strong>nnection sloping vertically upward:<br />
Support crossbar.<br />
00.3
The perfect connection<br />
General building inspections permit Z-9.1-651 • General building inspections permit Z-9.1-651 • G<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> ”One for all“<br />
Bolting in the wind suction safeguard<br />
(<strong>BiLO®</strong>-HK-bolt <strong>connector</strong>).<br />
00.4<br />
Orthogonal and slanted connection:<br />
Support crossbar.<br />
Pre-assembled connection without<br />
a shadow gap/support crossbar.<br />
Placing the hole for the wind<br />
suction safeguard, for example,<br />
on the secondary beam.<br />
Vertically upward slanted<br />
connection/support-bolt.<br />
Secondary beam or purlin<br />
connection to OSB outdoors.<br />
Installation without a shadow gap (e.g. support crossbar)<br />
ASSEMBLY INFORMATION:<br />
• The BiLO ® -<strong>UBt</strong>-<strong>connector</strong> is marked on the support crossbar on<br />
connections, for example, on supports and is bolted with diameter<br />
6 x 80 mm BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws under 90°.<br />
• The centre web (finger) points upward against the attachment direction.<br />
• BiLO ® -<strong>UBt</strong>-<strong>connector</strong> is marked according to the installation position on<br />
the secondary beam/crossbar and lowered 8.5 - 9 mm deep.<br />
• Place the BiLO ® -<strong>UBt</strong>-<strong>connector</strong> in the milled-out portion and fasten with<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws, diameter 6 x 80 mm under 90°.<br />
The centre web (finger) points down in the attachment direction.<br />
• The milled-out portion on the secondary beam/crossbar is omitted in<br />
connections with a shadow gap.<br />
SLANTED AND INCLINED CONNECTIONS:<br />
• The installation is as described above, however, diameter 6 x 50 mm<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws are used on the narrow sides of the beams<br />
(tip of beam).<br />
SECURING AGAINST ELEVATING FORCES:<br />
ASSEMBLY INFORMATION:<br />
• BiLO ® -HK-screw <strong>connector</strong>s may be installed at d1 = 8.0 mm according<br />
to general building inspection permit No. Z-9.1-667, in order to absorb the<br />
elevating forces.<br />
• A hole of diameter 5 mm is introduced in the direction of the upper edge of<br />
the secondary beam to precisely position the BiLO ® -HK-screw <strong>connector</strong><br />
by the longitudinal hole of the assembled BiLO ® -Ubt-<strong>connector</strong> on the<br />
secondary beam below an angle of ≤ 80°. The focus of the bolted part<br />
attached in the secondary beam should equal 10 d1 from the end of the<br />
secondary beam according to appendix 10 of the permit.<br />
• Based on pre-drilling, the load of the BiLO ® -HK-screw <strong>connector</strong> is reduced<br />
by 10% against extracting (authorized Nz i.e. Rax,k) (see Z-9.1-667).<br />
• After attaching the BiLO ® -<strong>UBt</strong>-<strong>connector</strong>, the BiRA ® -HK-screw <strong>connector</strong><br />
is bolted effortlessly and at a precise fit in at the required length up to the<br />
main beam through the hole in the secondary beam.<br />
Vertically downward slanted<br />
connection/support-bolt.<br />
®<br />
BiLO<br />
Z-9.1-651<br />
NRW 02<br />
Pre-assembled connection without<br />
a shadow gap/support crossbar.
eneral building inspections permit Z-9.1-651 • General building<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> ”One for all“<br />
DELIVERY SCOPE:<br />
207 601<br />
Type: 75-1<br />
207 602<br />
Type: 105-1<br />
Table: Characteristic values for the load capacity *).....for connection angles a = ß = 90° (orthogonal connections), the main beam (and/or support or wall)<br />
is located so that the connection remains without a momentum effect.<br />
Q i,k ... lateral force in insertion direction / Q r,k ... lateral force at a right angle to the insertion direction / Z k ... tensile force at a right angle to the connecting level.<br />
Dimensions <strong>BiLO®</strong> [mm]<br />
-<strong>UBt</strong>-<br />
Bolts<br />
characteristic values of the load capacity<br />
[kN] 2)<br />
per<br />
Dimensions<br />
Secondary beam<br />
[mm]<br />
Dimensions<br />
Main beam<br />
[mm]<br />
Item no.: Type: Width Height <strong>Co</strong>nnection Qi,k 3) Qr,k 3) Z k Suction Width Height Width 4) Height<br />
207 601 75-1 46 75 2 x 6 8,0 5,3 7,5 ≥ 64 ≥ 90 ≥ 100 ≥ 90<br />
207 602 105-1 46 105 2 x 8 11,0 7,3 7,5 ≥ 64 ≥ 120 ≥ 100 ≥ 120<br />
207 603 135-1 46 135 2 x 10 14,0 9,3 7,5 ≥ 64 ≥ 150 ≥ 100 ≥ 150<br />
207 604 105-2 80 105 2 x 12 18,0 12,0 15,0 ≥ 98 ≥ 120 ≥ 100 ≥ 120<br />
207 605 135-2 80 135 2 x 15 23,5 15,6 15,0 ≥ 98 ≥ 150 ≥ 100 ≥ 150<br />
207 606 165-2 80 165 2 x 18 28,0 18,6 15,0 ≥ 98 ≥ 180 ≥ 100 ≥ 180<br />
207 607 135-3 114 135 2 x 20 32,5 21,6 22,5 ≥ 132 ≥ 150 ≥ 100 ≥ 150<br />
EFFICIENT TIMBER JOINTS!<br />
Depending on the<br />
BiRA ® -HK-bolt <strong>connector</strong><br />
[Z-9.1-667]<br />
Fastene: BiLO ® -<strong>UBt</strong>-bolts, diameter 6.0 x 80 mm (i.e. diameter 6.0 x 50 mm for a and/or b ≤ 90°).<br />
1) a..Horizontal angle, b..Vertical angle..always between the main beam (i.e. support or wall) and secondary beam.<br />
In (horizontal) slanted (30° ≤ a < 90°) or (vertical) inclined (30° ≤ b < 90°) connections, the values Q i,k and/or Q r,k must be multiplied by<br />
factor ks = [ ( 1-sin5 (90° - a)) x ( 1-sin3 (90° - b) ] m . (m = 0,5 bzw. 0,7 depending on the positioning of the main beam).<br />
(e.g.: a = 60°, b = 45°, m = 0,7 ks = [ 0,969 x 0,646 ] 0,7 = 0,720).<br />
2) Values only apply for a single load from Q i,k oder Q r,k oder Z k (Load combinations and planned momentum effect are regulated in the<br />
permit by additional verifications).<br />
3) Table values Q i,k bzw. Q r,k must be multiplied by 0.8, if the main beam and/or support or wall cannot freely turn (or slope accordingly)<br />
and via timbered joints and grain-cut timber - grain-cut timber connection for load reductions.<br />
4) For a double sided connection: Main beam width ≥ 120 mm.<br />
Prepared main beam.<br />
<strong>Co</strong>nnection without a shadow gap.<br />
207 603<br />
Type: 135-1<br />
Orthogonal and horizontally slanted<br />
connection main/secondary beam.<br />
207 604<br />
Type: 105-2<br />
Orthogonal connection<br />
main/secondary beam.<br />
207 605<br />
Type: 135-2<br />
207 606<br />
Type: 165-2<br />
®<br />
BiLO<br />
Z-9.1-651<br />
NRW 02<br />
Vertical upward sloped connection of<br />
the main/secondary beam.<br />
00.5
The perfect connection<br />
General building inspections permit Z-9.1-651 • General building inspections permit Z-9.1-651 • G<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> ”One for all“<br />
00.6<br />
BiROX ® -<br />
drive<br />
»T40«<br />
BiRA ® -HK-screw <strong>connector</strong><br />
BiLO ®<br />
Z-9.1-667<br />
NRW 02<br />
BiROX ® -drive »T25«<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws<br />
BiROX ® -drive »T25«<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws<br />
BiLO ®<br />
Z-9.1-651<br />
NRW 02<br />
BiLO ®<br />
Z-9.1-651<br />
NRW 02<br />
ACCESSORIES:<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws, part of permit Z-9.1-651.<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws were simultaneously developed with the<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> and are therefore precisely coordinated with<br />
the requirements.<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws are corrosion-protected according to DIN<br />
1052-2. The tried and proven BiROX ® -drive as well as the extra friction<br />
coating guarantee an easy attachment.<br />
PRODUCT ADVANTAGES:<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws and BiLO ® -<strong>UBt</strong>-<strong>connector</strong>s are matched to<br />
each other. One complete system from one location.<br />
Only BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws are needed.<br />
Additional fasteners (such as nails) are not required.<br />
Delivery scope:<br />
Item Dimensions. mm Head Drive <strong>Co</strong>ntent WG €<br />
No. d In Ig diameter unit unit<br />
Steel, high-gloss galvanized, blue chromated, packaged in cartons<br />
207 690 6,0 50 40 8,0 T 20 200 15<br />
207 691 6,0 80 70 8,0 T 20 100 15<br />
BiRA ® -HK-screw <strong>connector</strong><br />
Building-inspection approved under No.: Z-9.1-667<br />
BiRA ® -HK-screw <strong>connector</strong>s were developed for the structural timber<br />
construction. They are used to deflect lifting forces in conjunction with the<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> (forces against the inserting direction).<br />
A hole of diameter 5 mm is introduced in the direction of the upper edge of<br />
the secondary beam to precisely position the BiLO ® -HK-screw <strong>connector</strong><br />
through the longitudinal hole of the assembled BiLO ® -Ubt-<strong>connector</strong> on the<br />
secondary beam below an angle of ≤ 80°.<br />
The BiRA ® -HK-screw <strong>connector</strong> is bolted in effortlessly and precise after<br />
attaching the secondary beam through the hole at the desired length.<br />
BiLO ® -<strong>UBt</strong>-screw <strong>connector</strong>s are corrosion-protected according<br />
to DIN 1052-2.<br />
The tried and proven BiROX ® -drive as well as the additional friction coating<br />
guarantee an easy attachment.<br />
Item Dimensions mm Head Drive <strong>Co</strong>ntent WG €<br />
No. d In I1 I2 diameter unit unit<br />
Steel, high-gloss galvanized, yellow chromated, packaged in cartons<br />
527 595 8,0 160 75 75 9,8 T 40 100 15<br />
527 596 8,0 190 90 90 9,8 T 40 100 15<br />
527 597 8,0 220 100 100 9,8 T 40 100 15<br />
527 598 8,0 240 115 115 9,8 T 40 100 15<br />
527 599 8,0 300 140 140 9,8 T 40 100 15<br />
Placing the hole for the wind suction safeguard,<br />
for example, on the secondary beam.<br />
Bolting in the wind suction safeguard<br />
(BiLO ® -HK-bolt <strong>connector</strong>).
eneral building inspections permit Z-9.1-651 • General building<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> ”One for all“<br />
Advantages of the BiLO ® -<strong>UBt</strong>-<strong>connector</strong>s:<br />
1). Invisible connection.<br />
2). Easy and powerful plug-in connection.<br />
3). Load reduction of lateral forces (Q i,k ) in the inserting direction and<br />
laterally toward the inserting direction (Q r,k ) as well as tensile<br />
forces (Z k ).<br />
4). Load reduction of suction forces (against the inserting direction)<br />
in conjunction with BiRA ® -HK-screw <strong>connector</strong>s (Z-9.1-667).<br />
5). No gap formation.<br />
6). Reduction of the assembly time as well as a calculation advantage.<br />
7). Great pre-manufacturing standard.<br />
8). Usable for timber cross-sections from 64 / 90 mm.<br />
9). Quick and easy assembly.<br />
10). Low sinking depth of 8.5 - 9.0 mm. The cross-section reduction<br />
is generally negligible.<br />
11). <strong>Co</strong>nnections of various material combinations<br />
(e.g. solid wood materials).<br />
12). Time-saving and efficient assembly of pre-manufactured<br />
complete elements.<br />
Ridge connection installed laterally with shadow gap<br />
<strong>connector</strong>.<br />
Main/secondary beam connection,<br />
main beam is vertically sloped.<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screw<br />
Orthogonal connection: Main/secondary beam.<br />
Pre-assembled connection with shadow<br />
gap/tanner‘s purlin.<br />
BiLO ®<br />
Z-9.1-651<br />
NRW 02<br />
Orthogonal and slanted connection/support-bolt.<br />
Orthogonal and horizontally sloped connection of<br />
the main beam - secondary beam.<br />
Vertical downward sloped connection of<br />
the main /secondary beam.<br />
Pre-assembled connection without a shadow gap/<br />
support crossbar.<br />
Orthogonal and horizontally sloped connection of<br />
the main beam - secondary beam.<br />
Vertical upward sloped connection of<br />
the main /secondary beam.<br />
<strong>Co</strong>nnecting a tanner‘s purlin with a shadow gap. Secondary beam or purlin connection to OSB<br />
outdoors.<br />
BiRA ® -HK-screw <strong>connector</strong> (wind suction safeguard)<br />
00.7
The perfect connection<br />
<strong>BiERBACH</strong> ® <strong>GmbH</strong> & <strong>Co</strong>. <strong>KG</strong> Rudolf-Diesel-Straße P.O. Box 1250 Telephone: 02303 / 28 02-0<br />
Befestigungstechnik D-59425 Unna D-59402 Unna Fax: 02303 / 28 02-129<br />
Express delivery service::<br />
Direct contact<br />
Fax: 02303 / 28 02-143<br />
Email: info@bierbach.de<br />
Internet: http://www.bierbach.de<br />
10 Fastening technology<br />
20 Timber construction<br />
technology<br />
30 Nail Technology<br />
40 Screw Technology<br />
50 Powder actuated<br />
fastening technology<br />
Production programme<br />
Fastening systems<br />
<strong>BiERBACH</strong> ® -dealers: <strong>BiERBACH</strong> ® -Customer Service:<br />
1.000 AD 10/2008