PRESSURE PREDICTION AND CONTROL<br />

where,<br />

R = ft/hr<br />

N = rpm<br />

W = lb<br />

D = diameter in inches.<br />

As predicted, plotting “d” as calculated from this equation versus depth does establish<br />

recognizable trends in normally pressured formations and recognizable deviation from these<br />

trends as abnormal pressures are encountered.<br />

In 1971, Rehm and McClendon proposed that if it were possible to correct for fluid weight, the<br />

“d” value could be related directly to formation pressure rather than to differential pressure.<br />

They suggest making a correction by multiplying the basic “d” value by the ratio of the normal<br />

fluid weight pressure gradient for the area to the actual fluid weight being used.<br />

⎛ Normal Fluid Weight<br />

d xc = d<br />

⎟ ⎞<br />

⎜<br />

⎝ Fluid Weight in Use ⎠<br />

Use of this correction factor gives excellent results and permits graphic determination of<br />

pressure gradients in abnormally pressured zones.<br />

Gas Content of <strong>Drilling</strong> Fluid<br />

Increases in the gas content of a drilling fluid was recommended as an indicator for detecting<br />

abnormal pressure zones as early as 1945 (Pixler). Since experience has shown that gas cutting<br />

is not always a result of an under-balance condition, correct interpretation of gas cutting trends<br />

is imperative.<br />

Gas may be entrained in the fluid column as a result of the following conditions.<br />

• When a formation containing gas is drilled, cuttings and cavings containing gas are circulated up<br />

the hole. Hydrostatic pressure on these particles is reduced. Gas in the particles expands and is<br />

released to the drilling fluid system, cutting the weight. In such cases, increasing fluid weight will<br />

not stop the gas cutting. This condition can be verified by reducing drilling rate or by stopping<br />

drilling and circulating bottoms up.<br />

• While drilling a pressured formation, the differential between the hydrostatic fluid column<br />

pressure and formation pressure is reduced. During a connection or trip, the piston effect of<br />

upward pipe movement can swab formation gases and fluids into the wellbore. As the fluid or gas<br />

is circulated up the annulus, gas (if present) will expand. When detected, the gas is generally<br />

concentrated and reaches the surface at the same time, thereby showing a significant gas cut.<br />

When using gas in the drilling fluid as an indicator of abnormal pressure, a gas detector unit of<br />

some type is required. A trend of background gas and connection gas can be noted as drilling<br />

progresses. Both background gas and connection gas normally increase slowly with depth. Any<br />

sudden increase in background or connection gas should be watched carefully and taken as a<br />

possible warning of increasing pore pressure.<br />