FLOW CHART E. UNBALANCED GENERATOR OUTPUT VOLTAGE<br />

START<br />

Remove load at generator terminals. Is output<br />

Check for correct grounding of generator<br />

still unbalanced? and load.<br />

Yes<br />

I . I I 1<br />

I tno-l<br />

I<br />

Are generator leads connected and grounded<br />

properly? See Figure 36, <strong>page</strong> 34.<br />

Correct as necessary.<br />

I I t I<br />

Is generator stator winding continuous per<br />

TEST [K]?<br />

Check load for ground faults and correct as<br />

necessary.<br />

25<br />

Replace stator assembly.