• Case 2: Terminal ID = “2” ~ “32”<br />

IP ADDRESS<br />

OK?<br />

AUTO<br />

Yes<br />

——— Select “MAUAL”, if you want to enter IP address manually.<br />

(IP address setting line will appear on the screen.)<br />

——— Press to continue.<br />

* The IP address of each terminal should be the unique number from 192.168. 0. 1 to 192.168.255.255.<br />

Declare terminal configuration<br />

Date 01-10-10<br />

Time 12:34 00<br />

ID Character MC #01<br />

Check System Master<br />

Check Cluster ID 0<br />

R/J/Order Printer1 No<br />

R/J/Order Printer2 No<br />

R/J/Order Printer3 No<br />

Slip Printer No<br />

——— Enter date if it is wrong.<br />

——— Enter time if it is wrong.<br />

——— Within 12 characters<br />

——— Master / Backup master / Satellite / Self master<br />

——— Enter cluster No. “1” ~ “9”, if using check cluster system.<br />

——— No printer / UP-350 / UP-360 / SA-3015 / UP-250 for<br />

R/J or Order printer.<br />

——— No printer / SA-3015 / SP-1300<br />

OK?<br />

YES<br />

Program restoration<br />

——— Press to continue.<br />

INIT 10-10-01 12:34 000001<br />

AUTO PGM<br />

1.No Restore / Receive<br />

2.PGM Restore (CF Card)<br />

3.PGM Receive (Inline)<br />

——— Select, if no need to download any data.<br />

——— Select to download a program data from CF card.<br />

——— Select to download a program data from other terminal.<br />

• Restore from CF card.<br />

Insert the CF card into the slot and select the appropriate file and press the key.<br />

• Program receive from other terminal.<br />

INIT 10-10-01 12:34 000001<br />

Receive Data<br />

All PGM<br />

——— All Data (including totalizer) / All PGM (program only)<br />

PGM Receive from MC #05<br />

——— Select the machine to send the data.<br />

OK?<br />

YES<br />

Note:<br />

In case of using wireless inline, we recommend that you should change the ESS ID / WEP KEY<br />

character for your security.<br />

2-1-2. How to initialize the terminal (add / replace one terminal)<br />

Preparation:<br />

1. All peripheral devices and terminals of this cluster should be turned off.<br />

2. Connect all of the peripheral devices (such as printer, display etc.) to this terminal.<br />

3. Connect the added / replaced terminal to inline.<br />

Operation:<br />

Follow the steps shown on the page 5 to 6.<br />