Dust Nuisance at Fuel Feed System in AFBC boiler

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4. From the current read<strong>in</strong>gs of PA fan, we could see th<strong>at</strong> the PA fan was oper<strong>at</strong><strong>in</strong>g with utterly low<br />

efficiency. We advised to carry out the performance test<strong>in</strong>g of PA fan <strong>in</strong>situ. The performance<br />

test done <strong>at</strong> fan manufacturers’ works would be with a test rack th<strong>at</strong> is done without IGV /<br />

without a suction box. There can be duct<strong>in</strong>g eng<strong>in</strong>eer<strong>in</strong>g defect which can cause poor<br />

performance of the PA fan. Many cases have been observed to be rel<strong>at</strong>ed to poor <strong>in</strong>let conditions.<br />

Photo 2 & 3: It is seen the protective co<strong>at</strong><strong>in</strong>g by phoscast is seen dislodged. Right above the<br />

fuel nozzles only the erosion is seen. This can happen due to high fuel l<strong>in</strong>e air flow.