PUBLIC AREAS<br />

Main Ballroom Requirements (continued)<br />

Provide windows where possible, yet room must be capable of complete black out.<br />

Minimum clear height of 18' 0" ( 5.5 m)under chandeliers and lowest ceiling level.<br />

All walls, including movable partition walls to have a sound rating of not less than 54<br />

dB (FSTC 54).<br />

Clear automobile access route must be provided to the ballroom together with an 8' 0"<br />

(2.4 m) wide pair of entry doors or removable panel.<br />

Ceiling design must incorporate anchor/suspension points for scenery etc. and power<br />

outlets/suspension bars for special lighting. Align pot lights with structural beams or<br />

special support beams - with the removal of the light can, the beam can be used to<br />

support a lighting truss, scenery anchors etc.<br />

A motorised projection screen is required at each end of the ballroom. The screen<br />

(approximately 14' 0" wide x 14' 0" high – 4.3 x 4.3 m)and the retaining box shall be<br />

mounted above the ceiling so that the screen is completely concealed when not in use.<br />

The switch operating the screen will be mounted on the wall in the adjacent control<br />

niche. The screen shall be without borders and with matt white reflective surface.<br />

Main ballroom to be sub-divisible into halves (double layer of partitioning) and thirds<br />

(single layer of partitioning).<br />

Each ballroom subdivision must be able to function independently i.e. there must be<br />

provision for each to locally control:<br />

a) Background music volume and on/off<br />

b) Sound reproduction through background music speakers in lieu of<br />

background music<br />

c) Head table and runway lighting<br />

d) General lighting dimming<br />

e) Remote control of lighting should also be available to enable light<br />

levels to be controlled by an audio-visual operator running a slide<br />

show.<br />

Each ballroom subdivision must incorporate:<br />

a) Supply air system with local control thermostat<br />

b) Exhaust air system<br />

c) Baseboard electrical requirements as shown on Fairmont Hotels<br />

and Resorts Standard Details.<br />

REV. MARCH 2006 77<br />