<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

PUBLIC AREAS<br />

5. BALLROOMS AND MEETING ROOMS<br />

5.1. General Requirements<br />

Ballrooms are to be designed to suit the requirements of the incentive group market.<br />

These groups use the rooms for major promotions as well as normal dinner and social<br />

functions.<br />

The Ballroom/meeting area foyer must relate directly with the main entry lobby by the<br />

public corridor. The requirements will be similar to those expressed under the main<br />

entry lobby section of these Design Standards.<br />

The circulation area serves as the main arrival and control point and it should<br />

accommodate business center, meeting coordinator, coat checkroom, phone and public<br />

washroom facilities.<br />

The lobby circulation links the pre-function area to the facility's main entrance and to<br />

the hotel's public circulation. The coat-check room, guests’ washrooms and telephones<br />

should be adjacent to it.<br />

Entrance to have direct access to guestroom service (luggage) elevators.<br />

All exposed grilles, diffusers, sprinkler escutcheons, speakers, etc shall be factory<br />

painted to match adjacent surface.<br />

Ductwork behind grilles and diffusers to be painted matt black.<br />

Where high temperature producing equipment is located beneath, above or adjacent to<br />

public areas, a special insulating wall or ceiling is to be provided to prevent heat<br />

transmission to these areas.<br />

Where very noisy and/or vibrating equipment is located beneath, above or adjacent<br />

public areas, a special isolating wall or ceiling is to be provided. This wall or ceiling is<br />

in addition to providing antivibration mountings for individual pieces of equipment.<br />

All walls to have a sound rating of not less than 54 dB (FSTC 54).<br />

5.2. Ballroom Pre-function Space<br />

Pre-function space (approximately 40% of net ballroom area) should accommodate<br />

group reception and registration area and provide assembly space for ballrooms and<br />

meeting rooms at beginning, intermission and post function activities and be private and<br />

separate from the hotel general circulation areas.<br />

Portable group registration desks (FF & E) shall have the following voice/data<br />

provisions should be concealed in the wall behind a baseboard access panel at each desk<br />

location:<br />

a) Duplex electrical outlets (UPS) for computer system (CRT,<br />

keyboard and printer)<br />

REV. MARCH 2006 75<br />