PUBLIC AREAS<br />

Swimming Pools and Whirlpool (continued)<br />

b) Chaises arranged in groups of two with small table between<br />

c) Sufficient cabanas should be provided for 25% of chaises.<br />

There should be a minimum of one service cabana and it should contain a 6’ 0” x 8’ 0”<br />

x 2’ 0” (1.8 x 2.4 x 0.6 m) L-shaped storage counter (provided by the General<br />

Contractor) and finished with a material to withstand weather, with sufficient storage<br />

shelving with lockable hinged doors for one day’s towel par – two towels per chaise x<br />

two changes per day, i.e., total of four per chaise per day. (200 Towels = approx. 5’ 0”<br />

x 5’ 0” x 2’ 0” – 1.5 x 1.5 x 0.6 m) and two lockable drawers, 4” (10 cm) deep. Also,<br />

two telephone outlets and computer system outlet, as well as space for dirty towel cart<br />

(40” l x 29” w x 39” h – 102 x 74 x 99 cm), garbage pail, cold water dispenser and ice<br />

chest.<br />

All service cabanas must have good access route to and from service cabanas for towel<br />

delivery and collection. Provide shower and footpath at location of entry to pool deck<br />

from beach area and at all pathways leading from beach.<br />

For maintenance purposes provide a ¾” (1.9 cm) hose bibb at 150 ft (45 m) centers for<br />

washing deck together with a waterproof duplex outlet.<br />

Provide weatherproof speakers with volume control at pool bar.<br />

Proper windbreaks – glass screens, landscaping, berms – must be provided to shelter<br />

deck. Wind also dictates care when sighting waterfalls, fountains, etc.<br />

3.13. Outdoor Recreational Facilities<br />

Facilities may include, but are not limited to the following:<br />

Tennis courts:<br />

a) All courts shall be lighted using the latest non-glare lighting<br />

fixtures<br />

b) Plastic coated metal fence 10’0” high with 4’0” wide (3.0 x 1.2 m)<br />

access gate to surround each court. Where two courts are side by<br />

side, fencing between courts should be removable for possible<br />

tournament seating<br />

c) Allow for a covered seating at side of courts<br />

d) Duplex electrical outlet at each end of court for ball machine<br />

e) Hose bibb for washdown and court maintenance<br />

f) Waiting area with duplex electrical outlets for small fridge<br />

(FF&E), washrooms, telephones and storeroom (approximately<br />

100 ft 2 – 9.3 m 2 )<br />

REV. MARCH 2006 70<br />