09.06.2017 Views

FAIRMONT HOTELS & RESORTS -DESIGN STANDARDS

Hotel Design

Hotel Design

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

PUBLIC AREAS<br />

Three Meal Restaurant (continued)<br />

Maitre d’s station is to incorporate the following features:<br />

a) Multi-line telephone and base station for cordless telephone<br />

b) A 110V x 15<strong>amp</strong> duplex electrical outlet<br />

c) Recessed light fixture to illuminate writing surface<br />

d) Sloped writing surface with drawer and cabinet with adjustable<br />

shelves.<br />

Service stands (FF & E) (one every 35 seats) shall be provided at locations not<br />

immediately adjacent to a seating arrangement. The incandescent lighting level in the<br />

service stand area is to be kept as low as practical with a local wall box dimmer. Each<br />

service stand will require the following features:<br />

a) Duplex electrical outlet (UPS) for point of sale and telephone<br />

b) Point of sale cable outlet<br />

c) Telephone<br />

d) Duplex electrical outlets.<br />

Coat check storage space (approximately 45 ft 2 - 4.2 m 2 ) adjacent the maitre d' station.<br />

Locate room lighting dimming control, background music volume control and ceiling<br />

fan control at a service stand and out of guests’ sight or in a control niche adjacent the<br />

maitre d’s stand.<br />

2.5. Specialty Restaurant<br />

This restaurant should provide a fine dining experience for hotel guests (allow 30 ft 2 –<br />

2.8 m 2 per seat). It is very important that the interior design of the room creates a rich,<br />

warm, friendly and welcoming ambience without being formal. Main entry doors<br />

should be of “open” design, e.g., wrought iron to be able to showcase the room when<br />

closed.<br />

The Specialty Restaurant should be easily accessible from the main lobby and adjacent<br />

or linked to the main kitchen. It should be visible from the public circulation area.<br />

Exterior views from the dining area are desirable.<br />

Service vestibule, service stations, maitre d' station, coat check and table mix<br />

requirements similar to Three Meal Restaurant.<br />

Locate room lighting dimming control and background music volume in a control niche<br />

adjacent the maitre d’s stand.<br />

Table sizes and mix similar to Three Meal Restaurant.<br />

REV. MARCH 2006 62<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!