<strong>FAIRMONT</strong> <strong>HOTELS</strong> & <strong>RESORTS</strong> · <strong>DESIGN</strong> <strong>STANDARDS</strong><br />

PUBLIC AREAS<br />

B. PUBLIC AREAS<br />

1. LOBBY AND CIRCULATION<br />

1.1. Main Entrance and Lobby<br />

Provide a porte cochère to protect the entrance lobby from the weather and appropriate<br />

spaces to assist arriving and departing guests. The entrance design must leave the guests<br />

with an excellent first and last impression.<br />

Luggage handling activities should not interfere with the guests’ entrance and direct<br />

access to valet parking office, bellmen’s store, service elevators, luggage storage, etc.<br />

The entrance lobby is to be adjacent to the vehicle arrival location and connects directly<br />

to the main lobby.<br />

A taxi holding area and valet parking holding area adjacent to porte cochere.<br />

Porte cochere width should be not less than 40' 0" (12.2 m) with three driveway lanes.<br />

Clear height should be not less than 10' 0" (3.0 m) to curb line and 14' 0" (4.3 m) over<br />

driveway.<br />

Adequate drainage must be provided and the driveway sloped accordingly.<br />

The sidewalk outside main entrance doors should be not less than 15' 0" (4.6 m) wide<br />

and minimum distance between columns and curb line shall be 4' 0" (1.2 m). Elsewhere<br />

the sidewalk should be 10' 0" (3.0 m) wide. Curb to be approximately 4" (10 cm) high<br />

and in contrasting material to sidewalk and driveway paving so as to be clearly visible<br />

to pedestrians. Two 3' 0" (91 cm) wide curb drops to be incorporated in curb.<br />

In cold climates overhead radiant heating is required outside main entrance doors.<br />

Heaters are to be controlled by a thermostat and a time clock with manual override.<br />

Electric snow melting must be incorporated in sidewalk in climates with heavy<br />

snowfall.<br />

Weatherproof duplex electric outlets are required for maintenance of the area. A screw<br />

down, recessed 3/4" (2 cm) cold water hose bib for washing down. 110V x 20 <strong>amp</strong><br />

weatherproof outlet (separate circuit) for high-pressure hose unit.<br />

Landscape planters must have sufficient drains, duplex outlets and hose points are to<br />

ensure proper plant lighting and maintenance.<br />

Three anodised aluminium finish of a colour selected with internal halyards flagpoles<br />

shall be provided at the porte cochere. If freestanding, they shall be not more than 40'<br />

0" (12.2 m) high and less than 15’0” (4.6 m) high.<br />

REV. MARCH 2006 53<br />