09.06.2017 Views

FAIRMONT HOTELS & RESORTS -DESIGN STANDARDS

Hotel Design

Hotel Design

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fairmont Hotels & Resorts · Design Standards<br />

APPENDICES<br />

Public Washroom Stall Door (continued)<br />

e) Wall bumper (RO) 409 US10B<br />

f) Coat hook (VA) Interior Designer to select US10B<br />

g) Door silencer (RO) 608<br />

2.18 Ballroom and Meeting Room Entry Doors – (Pair with standard exiting devices):<br />

a) Floor closers (DM) BTS 80 EMB/F 613E<br />

b) Pivots (DM) 75233 613<br />

c) Power transfer (VO) EPT2 SP313<br />

d) Exit devices (SA) 12 56 WD 8610 F113 less pull US10B<br />

e) Mortise cylinder as required<br />

f) Decorative pulls Interior designer to select<br />

g) Sound seal (DH) Cush n’ seal White<br />

h) Power supply (SA) 3530<br />

i) Key switch (SA) 4374<br />

* Doors normally closed and secured. Access by key at all times. Egress free at<br />

all times. When power is turned on by key switch, doors may be held in open<br />

position by floor closer. Power on by second key switch holds exit device<br />

latches retracted, allowing doors to be “push/pull”. Fire alarm condition cuts<br />

power allowing doors to close and latch.<br />

2.20 Ballroom and Meeting Room Service Doors (Pair):<br />

a) Floor closer (DM) BTS 80 EMB/F 613E<br />

b) Pivot (DM) 75233 613E<br />

c) Power transfer (VO) EPT 2 SP313<br />

d) Exit device (SA) 12 56 8810 G US10B<br />

e) Wall bumper (RO) 409 US10B<br />

f) Sound seal (DH) Cush n’ Seal White<br />

g) Power supply (SA) 3530<br />

h) Key switch (SA) 4370<br />

REV. MARCH 2006 262<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.