Fairmont Hotels & Resorts · Design Standards<br />

SERVICES AND SYSTEMS<br />

UTP Cables<br />

a) The modular cord assembly shall meet or exceed the short link NEXT requirements of 38<br />

dB when tested with enhanced Category 5 connecting hardware.<br />

b) The modular cord cable shall be 4-pair, with 24 AWG solid or stranded copper<br />

conductors.<br />

c) The modular cord assemblies shall be 10 feet in the guest rooms, and 4 feet for patching<br />

in the wiring closets.<br />

d) Modular cross over cables will be four feet in length with a yellow cable jacket.<br />

e) The modular cord assembly shall meet the requirements per the latest issue of<br />

ANSI/TIA/EIA-568.<br />

f) The modular cord assembly shall meet the requirements per the latest issue of ISO/IEC<br />

11801.<br />

REV. MARCH 2006 237<br />