Fairmont Hotels & Resorts · Design Standards<br />
SERVICES AND SYSTEMS<br />
Administration Specifications<br />
All cable shall be 4-pair enhanced category 5, unshielded twisted pair cable. All cabling shall<br />
be in a metal or PVC conduit. Where conduit is not provided in existing hotels, cable shall be<br />
plenum rated where regulation require.<br />
a) Voice<br />
b) Data<br />
Each telephone line will be run with Cat 5 e cable (see section 7.1, distance<br />
applies to Data only), as well all jacks must terminated on RJ-11 jacks and<br />
installed onto a quad jack faceplate. Voice RJ-11 jacks must be terminated with a<br />
BLACK Connector/Jack.<br />
Each workstation area shall have:<br />
Two RJ-11C terminations.<br />
Each data line will be run with Cat 5 e cable (see section 7.1), terminated on an 8<br />
wire, 8-position jack. Each RJ-45 Data connection will be terminated with a<br />
BLUE Data jack.<br />
Each workstation area shall have:<br />
Two RJ-45 terminations.<br />
Meeting and Ballrooms Specifications<br />
All cable shall be 4-pair enhanced category 5, unshielded twisted pair cable. All cabling shall<br />
be in a metal or PVC conduit. Where conduit is not provided in existing hotels, cable shall be<br />
plenum rated where regulation require.<br />
Each meeting room and divisible section of meeting rooms or ballrooms shall have at least, one<br />
quad jack faceplate with two RJ-11C terminations and two RJ-45 terminations for data. Each<br />
voice and data line will be run with Cat 5 e cable (see section 7.1, distance applies to Data<br />
only). This jack shall be mounted in an appropriate A/V niche to provide maximum service to<br />
the space, usually at the front or side of the room. Voice RJ-11 jacks must be terminated with a<br />
BLACK Connector/Jack.<br />
Each divisible section of a large meeting rooms and all sections of ballrooms shall have one 6-<br />
plex jack with each jack terminated as RJ-11 C for voice. In addition it shall also have at least,<br />
one quad jack faceplate with two RJ-45 terminations for data. Each voice and data line will be<br />
run with Cat 5 e cable (see section 7.1, distance applies to Data only). These jacks shall be<br />
mounted in an appropriate A/V niche to provide maximum service to the space, usually at the<br />
front or side of the room.<br />