Fairmont Hotels & Resorts · Design Standards<br />

SERVICES AND SYSTEMS<br />

6. TECHNOLOGY SERVICES – DATA CABLING SPECIFICATIONS<br />

6.1. Equipment Price Breakdown<br />

a) The network cabling contractor shall provide a price breakdown, included in<br />

response to defined scope of work, for voice and data cabling, terminations, patch<br />

panels and certification as specified below. Rough in consisting of conduit, boxes<br />

and pull string to be included as specified. Conduiting to be provided by the<br />

electrical contractor.<br />

b) The network cabling contractor shall provide a closet-by-closet price breakdown as<br />

outlined in the ex<strong>amp</strong>le below. This will start with the main computer room, then<br />

move up to subsequent wiring closets on each of the guest floors. The network<br />

cabling contractor will supply a summarized grand total at the end of the quote.<br />

c) Additional items requested will be itemized in the same manner as shown below.<br />

The contractor will supply a separate summarized grad total with those numbers<br />

included.<br />

d) The need to amend or modify the installation specification may arise. The hotels<br />

representative prior the installation must approve any changes or amendments.<br />

Ex<strong>amp</strong>le of a price breakdown per floor data<br />

Main Computer Room<br />

Product/Manufacturer Quantity Price<br />

CAT 5e plenum rated jacket horizontal wiring<br />

RJ45 Data connection in guest room<br />

10 ft. CAT 5e patch cord for guest room<br />

48 Port HD horizontal termination<br />

24 Port HD horizontal termination<br />

4 ft. CAT 5e patch cords for IDF<br />

6 Strand 50/125 um Multi mode fiber backbone, with flex<br />

conduit to computer room.<br />

Fiber rack mount patch panel “ 6 port SC termination”<br />

SC connectors<br />

6 ft. SC – SC fiber patch cables<br />

4 ft Wall mount cabinet with fan.<br />

19 inch. Rack mount surge protected power bar. “Min 6 port”<br />

TOTAL MATERIAL<br />

LABOR<br />

TOTAL<br />

REV. MARCH 2006 221<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.