Fairmont Hotels & Resorts · Design Standards<br />

SERVICES AND SYSTEMS<br />

4. ELEVATORS<br />

4.1. General Requirements Public Elevators<br />

Specifications are based upon Otis elevator equipment to establish a type and level of<br />

quality. Similar equipment manufactured by other elevator companies is acceptable,<br />

subject to approval by Fairmont Hotels and Resorts.<br />

The following standard features are required in each elevator:<br />

a) Average waiting time of under 30 seconds<br />

b) Load factor of approximately 30%<br />

c) Total trip time of less than 70 seconds<br />

d) (For the purposes of calculating items a, b and c assume an average of 1<br />

½ persons per room for a urban hotel and 2 persons per room for a resort<br />

at 100% occupancy.)<br />

e) Duty to be 3,500 lbs (1,580 kg)<br />

f) Speed for a hotel of less than ten floor 350 feet (107 m) per minute and<br />

exceeding ten floors of 500 (152 m) feet per minute<br />

g) Every guest or public floor is to have a stop and an opening<br />

h) Public area floors are to have 3’6” (1.1 m) centre opening, flush doors<br />

with polished bronze, acid etched doors<br />

i) Guestroom floors are to have 3’6” (1.1 m) centre opening, flush doors<br />

with decorative door design<br />

j) Door frames are to be concealed filler frame type with painted finish and<br />

electronic detector<br />

k) Door sill to be bronze<br />

l) Hall lanterns are to type 6646DK with chimes and located adjacent to the<br />

door frames<br />

m) Each car is to have two car operating panels with round buttons,<br />

emergency stop switch, emergency call button, emergency service switch,<br />

close and open door buttons, interface with electronic card readers for<br />

Fairmont Gold floors and descriptive engraving for public facility floors<br />

buttons, background music speakers and an exhaust fan with sound level<br />

not exceeding NC 30<br />

n) The 8’6” (2.6 m) high car interiors will be based upon the Interior<br />

Designer’s drawings incorporating a handrail, mirrors, millwork,<br />

stonework and advertising panels<br />

o) The car is to incorporate emergency power with automatic selection and<br />

automatic levelling.<br />

REV. MARCH 2006 215<br />