Fairmont Hotels & Resorts · Design Standards<br />

SERVICES AND SYSTEMS<br />

3.4. Television System<br />

Television signal systems from satellites will be used wherever excellent reception and<br />

coverage is available. Where a satellite system is not available, a cable system is to be<br />

installed.<br />

The television terminal equipment will be located in a room (allow approximately<br />

75 ft 2 – 7 m 2 ) adjacent to the telephone equipment room.<br />

Pay per view television, where available, will be located in a room (allow<br />

approximately 150 ft 2 – 14 m 2 ) adjacent to the telephone equipment room. This<br />

equipment shall be supplied and installed by an independent supplier.<br />

The general contractor will be responsible for supplying the whole system, excluding<br />

the television sets. Televisions complete with remote controls will be supplied and<br />

installed by FF and E.<br />

A television signal outlet together with its attendant duplex electrical outlet is to be<br />

provided at the following locations:<br />

a) All guest bedrooms and living rooms<br />

b) All presidential and special suite bathrooms<br />

c) All public bars and lounges<br />

d) Secured storage rooms in maintenance areas<br />

e) At television repair workbench in maintenance area<br />

f) Employee dining room and employee lounge<br />

g) Ballroom, ballroom pre-function areas and meeting rooms<br />

h) Staff training room<br />

i) Health club relaxation areas and exercise rooms.<br />

Provide different designated equipment rooms for the hotel and meeting facilities<br />

operation.<br />

3.5. Closed Circuit Television Security and Assistance Systems<br />

A closed circuit television system shall be provided with wall mounted cameras located<br />

in the following areas:<br />

a) Swimming pool (wide angle type)<br />

b) Staff entrance<br />

c) All remote, unsecurable and unattended entrances or exits<br />

d) Food and beverage entrance doors<br />

e) Main lobby and front desk area (pin hole type)<br />

f) Cashier’s desk<br />

REV. MARCH 2006 210<br />

© 2002, Fairmont Hotels and Resorts. All Rights Reserved.